A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microwave Permittivity of Trace sp Carbon Impurities in Sub-Micron Diamond Powders. | LitMetric

Microwave dielectric loss tangent measurements are demonstrated as a method for quantifying trace sp-hybridized carbon impurities in sub-micron diamond powders. Appropriate test samples are prepared by vacuum annealing at temperatures from 600 to 1200 °C to vary the sp/sp carbon ratio through partial surface graphitization. Microwave permittivity measurements are compared with those obtained using X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and electron energy loss spectroscopy (EELS). The average particle size remains constant (verified by scanning electron microscopy) to decouple any geometric dielectric effects from the microwave measurements. After annealing, a small increase in sp carbon was identified from the XPS C 1s and Auger spectra, the EELS σ* peak in the C 1s spectra, and the D and G bands in Raman spectroscopy, although a quantifiable diamond to G-band peak ratio was unobtainable. Surface hydrogenation was also evidenced in the Raman and XPS O 1s data. Microwave cavity perturbation measurements show that the dielectric loss tangent increases with increasing sp bonding, with the most pertinent finding being that these values correlate with other measurements and that trace concentrations of sp carbon as small as 5% can be detected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6641517PMC
http://dx.doi.org/10.1021/acsomega.7b02000DOI Listing

Publication Analysis

Top Keywords

microwave permittivity
8
carbon impurities
8
impurities sub-micron
8
sub-micron diamond
8
diamond powders
8
dielectric loss
8
loss tangent
8
raman spectroscopy
8
microwave
5
carbon
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!