The fabrication of organic optoelectronic devices integrating asymmetric electrodes enables optimal charge injection/extraction at each individual metal/semiconductor interface. This is key for applications in devices such as solar cells, light-emitting transistors, photodetectors, inverters, and sensors. Here, we describe a new method for the asymmetric functionalization of gold electrodes with different thiolated molecules as a viable route to obtain two electrodes with drastically different work function values. The process involves an ad hoc design of electrode geometry and the use of a polymeric mask to protect one electrode during the first functionalization step. Photoelectron yield ambient spectroscopy and X-ray photoelectron spectrometry were used to characterize the energetic properties and the composition of the asymmetrically functionalized electrodes. Finally, we used poly(3-hexylthiophene)-based organic thin-film transistors to show that the asymmetric electronic response stems from the different electronic structures of the functionalized electrodes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6641596 | PMC |
http://dx.doi.org/10.1021/acsomega.7b00690 | DOI Listing |
Mikrochim Acta
January 2025
Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT).
View Article and Find Full Text PDFTalanta
January 2025
International Ph. D Program in Innovative Technology of Biomedical Engineering & Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan; Research Center for Intelligence Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan. Electronic address:
Nanocomposites that mimic the characteristics of enzymes, commonly as nanozymes, can function as an efficient sensing material with high selectivity towards the targeted biological macromolecule. These nanozymes overcome of the challenges that arise when using natural enzymes as sensing material. This study presents a novel nanozyme, Copper Selenite (CuSeO) nanoparticles mounted on f-CNF, to electrochemically determine a potential cardiovascular biomarker, Glutathione (GSH).
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Emotion, Cognition, & Behavior Research Group, Korea Brain Research Institute 61, Cheomdan-ro, Dong-gu, Daegu, 41062, Republic of Korea. Electronic address:
In this study, we present ECoGScope, a versatile neural interface platform designed to integrate multiple functions for advancing neural network research. ECoGScope combines an electrocorticography (ECoG) electrode array with a commercial microendoscope, enabling simultaneous recording of ECoG signals and fluorescence imaging. The electrode array, constructed from highly flexible and transparent polymers, ensures conformal contact with the brain surface, allowing unobstructed optical monitoring of neural activity alongside electrophysiological recordings.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
School of Materials Science and Engineering, Shandong Provincial Key Laboratory of Chemical Energy Storage and Novel Cell Technology, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, PR China. Electronic address:
The development of earth-abundant oxygen evolution reaction (OER) electrocatalysts with high activity and durability is critical for replacing noble-metal-based catalysts in the applications of scalable water electrolysis. A freestanding electrode architecture offers significant advantages over conventional coated powder forms due to enhanced kinetics and stability. However, precise control over electrode composition and the construction of uniformly distributed active sites within these electrodes remain challenging.
View Article and Find Full Text PDFEpilepsy Res
January 2025
Epilepsy Program, Division of Neurology, Department of Pediatrics, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada. Electronic address:
Background: Direct cortical electrical stimulation remains the gold standard for delineation of the primary motor cortex in patients with drug-resistant epilepsy (DRE) undergoing epilepsy surgery evaluation OBJECTIVE: This study aimed to explore the efficacy and safety of functional motor mapping through Stereo-EEG (SEEG) electrode contacts in children with DRE at our institute.
Methods: We performed a retrospective analysis of children who underwent SEEG evaluation and functional cortical mapping via bipolar electrical stimulation at our institution between July 2020 and June 2024. Detailed clinical, radiological and neurophysiological variable were extracted; qualitative and quantitative variables were summarized using appropriate descriptive statistics.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!