To compare balloon-expandable covered stents (BECS) available for use as renal chimney grafts to the Advanta V12 approved for use with the Endurant endograft. A silicone model was manufactured based on preoperative computed tomography angiography (CTA) scans of a patient with a 7-cm juxtarenal aneurysm treated with an Endurant bifurcated endograft and an Advanta V12 covered stent for the 6-mm-diameter right renal artery. The model was placed in a flow box filled with a 37°C blood-mimicking solution equipped with a pulsatile pumping system (140/60 mm Hg). The tested BECS were the Advanta V12, the VBX, and the BeGraft+. A 36-mm-diameter Endurant II endograft with a 16-mm-diameter contralateral limb and a 6×59-mm BECS chimney graft were used in 9 consecutive tests (3 for each combination). After each implantation, the model was placed in the CT scanner, and 2 radiologists blinded to the test device independently measured the gutter areas and the patent chimney graft lumen at the level of the Endurant's suprarenal stent, at the level of the chimney's maximum curvature, and 10 mm inside the renal artery. The intraclass correlation coefficients (ICC) were calculated to assess interreader reliability. The mean gutter areas were 19.3±7, 20.2±8, and 22.3±8 mm for the Advanta, VBX, and BeGraft+, respectively (all p>0.05). At the level of the aortic endograft's suprarenal stent struts, the mean diameter of the Advanta V12, VBX, and BeGraft+ were 4.46±0.3, 4.12±0.4, and 4.12±0.3 mm, respectively (all p>0.05). At the level of the maximum chimney graft angulation, the mean diameters were 3.77±0.3, 4.16±0.1, and 3.74±0.3 mm, respectively (all p>0.05). In the right renal artery, the mean diameters were 3.91±0.2, 4.05±0.9, and 4.3±0.4 mm, respectively (all p>0.05). The ICCs varied between 0.7 and 0.9, indicating good agreement between readers. These in vitro findings showed comparable results between the Advanta V12 and the available BECS used in conjunction with the Endurant endograft according to the instructions for use. Further clinical evaluation is needed to confirm these results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1526602819872498 | DOI Listing |
Eur J Vasc Endovasc Surg
January 2025
German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany.
Objective: Half of re-interventions after fenestrated and branched endovascular aortic repair (FB-EVAR) are target vessel related. Regarding bridging stent choice, existing data are controversial. This meta-analysis aimed to evaluate the performance of Advanta V12/iCAST as bridging stent in FB-EVAR.
View Article and Find Full Text PDFEJVES Vasc Forum
May 2024
Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden.
Objective: Treatment of complex aortic aneurysms with the laser fenestration (ISLF) technique involves implantation of a balloon expandable stent graft (bSG) in the created fenestration. Adequate expansion of this bSG is of importance both to achieve seal and to ensure target vessel stability. This experimental study assessed the expansion rate of different bSGs in the ISLF setting using intravascular ultrasound (IVUS).
View Article and Find Full Text PDFJ Endovasc Ther
February 2024
Department of Surgery, Prince of Wales Hospital, Sydney, NSW, Australia.
Purpose: To compare procedural and long-term costs associated with the use of Balloon-Expandable Covered Stents (BECS) in the management of Aortoiliac Occlusive Disease (AIOD).
Materials And Methods: A cost-consequence model was developed to simulate the intra- and post-operative management of patients with AIOD from the perspective of private health-payers. The study assessed the costs of the LifeStream (BD, Franklin Lakes, New Jersey), iCAST/Advanta V12 (Getinge, Goteborg, Sweden), BeGraft Peripheral (Bentley, Hechingen, Germany), and Viabahn Balloon Expandable (VBX) (W.
J Endovasc Ther
November 2023
Department of Surgery (Division of Vascular Surgery), Medisch Spectrum Twente, Enschede, the Netherlands.
Objective: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability.
Design: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups.
SAGE Open Med
September 2023
Department of Cardiovascular Surgery, Faculty of Medicine, Manisa Celal Bayar University, Manisa, Turkey.
Objectives: The current study aims to report midterm results of patients treated with endovascular intervention, kissing stent, or covered endovascular reconstruction of the aortic bifurcation, for Trans-Atlantic Inter-Society Consensus C or D aortoiliac occlusive disease involving the aortic bifurcation.
Methods: Eighteen patients who have intermittent claudication or chronic limb threatening ischemia with Trans-Atlantic Inter-Society Consensus C or D aortoiliac occlusive disease involving the aortic bifurcation enrolled to the study between January 2018 and January 2021. Kissing stents, Advanta V12 (Atrium, Getinge Group), were used in 13 patients, and the covered endovascular reconstruction of the aortic bifurcation technique was used in 4 patients to reconstruct the aortic bifurcation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!