Active contours, or snakes, are widely applied on biomedical image segmentation. They are curves defined within an image domain that can move to object boundaries under the influence of internal forces and external forces, in which the internal forces are generally computed from curves themselves and external forces from image data. Designing external forces properly is a key point with active contour algorithms since the external forces play a leading role in the evolution of active contours. One of most popular external forces for active contour models is gradient vector flow (GVF). However, GVF is sensitive to noise and false edges, which limits its application area. To handle this problem, in this paper, we propose using GVF as reference to train a convolutional neural network to derive an external force. The derived external force is then integrated into the active contour models for curve evolution. Three clinical applications, segmentation of optic disk in fundus images, fluid in retinal optical coherence tomography images and fetal head in ultrasound images, are employed to evaluate the proposed method. The results show that the proposed method is very promising since it achieves competitive performance for different tasks compared to the state-of-the-art algorithms.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701547 | PMC |
http://dx.doi.org/10.1364/BOE.10.003800 | DOI Listing |
Clin Chem Lab Med
January 2025
Canadian Microbiology Proficiency Testing Program (CMPT), Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.
External quality assessment (EQA) enhances patient safety through the evaluation of the quality of laboratory-based and point of care testing. Regulatory agencies and accreditation organizations utilize the results and the laboratory's response to them as part of assessing the laboratory's fitness to practice. In addition, where EQA samples are commutable and the assigned value has been determined using reference measurement procedures (RMPs), EQA data contributes to the verification of metrological traceability of assays as part of the post-market surveillance of diagnostic (IVD) medical devices (IVD-MDs).
View Article and Find Full Text PDFClin Chem Lab Med
January 2025
Canadian Microbiology Proficiency Testing Program (CMPT), Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.
Providers of external quality assessment (EQA) programs evaluate data or information obtained and reported by participant laboratories using their routine procedures to examine properties or measurands in samples provided for this purpose. EQA samples must offer participants an equal chance to obtain accurate results, while being designed to provide results in clinically relevant ranges. It is the responsibility of the EQA provider to meet the necessary requirements for homogeneity, stability and some other properties of the EQA items in order to offer participants a fair, reliable and technically interesting EQA experience.
View Article and Find Full Text PDFJ Food Drug Anal
December 2024
Department of Production Engineering, National Institute of Technology Tiruchirappalli, 620015, India.
Nowadays, food preservation, quality maintenance, and safety are major emerging concerns in the food industry. Methods for removing pathogens from the outside surfaces of food products would be an effective way to prevent bacterial contamination. Nanotopographies found on natural surfaces have been shown to mechanically damage the membranes of foodborne bacteria.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
School of Physics and Astronomy, Institute of Natural Sciences and MOE-LSC, Shanghai Jiao Tong University, Shanghai 200240, China.
Chemically driven micromotors exhibit a pronounced affinity for nearby surfaces, yet the quantification of this motor-wall interaction strength remains unexplored in experiments. Here, we apply an external force to a self-electrophoretic micromotor which slides along a wall and measures the force necessary to disengage the motor from the wall. Our experiments unveil that the required disengaging force increases with the strength of chemical driving, often surpassing both the motor's effective gravity and its propulsive thrust.
View Article and Find Full Text PDFJ Med Syst
January 2025
Department of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!