One of the most important tools used to evaluate kidney function in the context of chronic kidney disease or other renal function related pathologies is the exploration of glomerular filtration rate (GFR). Iohexol is up to this moment a good candidate molecule for the GFR assessment since it exhibits minimum protein binding rates and minimum extra-renal clearance, being neither secreted nor reabsorbed at the tubular level. This study proposes and evaluates a new LC-MS/MS method for the iohexol determination from capillary blood, prelevated using volumetric absorbative microsampling (VAMS) systems. As an alternative to VAMS, a brand new HemaPEN device for micro-prelevation was also tested. A new high throughput sample preparation protocol adapted for iohexol quantification from whole blood VAMS samples was developed. The medium term stability study of iohexol in dried whole blood VAMS samples that was conducted showed a good stability of this molecule for up to 12 days. By collecting only 10 μL of blood, iohexol can be analyzed from dried whole blood VAMS samples for concentration ranges between 1 and 250 μg/mL. Due to the analyte stability in VAMS for up to 12 days, this approach might be successfully applied for GFR assessment for clinical cases allowing minimum invasiveness and even delayed analysis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702420 | PMC |
http://dx.doi.org/10.1016/j.jpha.2019.06.003 | DOI Listing |
J Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, University of Muenster, Muenster, Germany. Electronic address:
The number of prescriptions for new direct oral anticoagulants (DOACs) apixaban, edoxaban, rivaroxaban and dabigatran has increased exponentially in recent years, increasingly replacing the old gold standard, vitamin-K-antagonists. Due to their wide therapeutic range, therapeutic drug monitoring (TDM) is not required, although it has been proven that this could significantly reduce side effects. In order to develop a cost-efficient and simple method for the simultaneous detection of the DOACs and phenprocoumon, a new technology for sample preparation from capillary blood in the ambulant sector named VAMS® was integrated and an LC-MS detector with on-line solid phase extraction (SPE) applying a Turboflow HTLC Cyclone 1.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Department of Pharmaceutical Chemistry and Pharmaceutical Analysis, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 03, Hradec Králové, Czech Republic. Electronic address:
Background: Microsampling of biological fluids followed by innovative sample pre-treatment reflects trends in bioanalytical chemistry. Volumetric absorptive microsampling (VAMS) enables exact whole blood volume collection and reduces the impact of hematocrit on the assay. In animal studies, it complies with the 3R principles (refine, reduce, replace).
View Article and Find Full Text PDFJ Proteome Res
January 2025
Sangui Bio Pty Ltd, Sydney 2065, Australia.
Diagnosis of non-small cell lung cancer (NSCLC) currently relies on imaging; however, these methods are not effective for detecting early stage disease. Investigating blood-based protein biomarkers aims to simplify the diagnostic process and identify disease-associated changes before they can be seen by using imaging techniques. In this study, plasma and frozen whole blood cell pellets from NSCLC patients and healthy controls were processed using both classical and novel techniques to produce a unique set of four sample types from a single blood draw.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2025
Laboratoire de Toxicologie, Fédération de Toxicologie, Hôpital Lariboisière AP-HP, 2 Rue Ambroise Paré, 75010, Paris, France.
Transplant Direct
December 2024
Department of Transplantation Medicine, Oslo University Hospital, Oslo, Norway.
Background: Hyperkalemia is common in kidney transplant (KTx) recipients. Patiromer, a potassium-binding polymer used to treat acute and chronic hyperkalemia, has the potential to bind charged particles in the gastrointestinal tract and thereby potentially affect the absorption of coadministered drugs. The immunosuppressive drug tacrolimus (Tac) has a narrow therapeutic window, is susceptible to drug-drug interactions (DDIs), and a potential gastrointestinal interaction with patiromer could elevate the risk of allograft rejection.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!