A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@rgos&datetype=edat&usehistory=y&retmax=5&tool=pubfacts&email=info@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel sonochemical synthesis of FeO nanospheres decorated on highly active reduced graphene oxide nanosheets for sensitive detection of uric acid in biological samples. | LitMetric

In this study, a super-active Iron (II, III) oxide nanospheres (FeO NPs) decorated reduced graphene oxide (rGOS) nanocomposite was developed. FeO NPs were stabilized on rGOS through electrostatic interactions in the aqueous medium. This process involves an ultrasound assisted reduction reaction of the GOS. The as-synthesized FeO NPs@rGOS was characterized through the HRTEM, SEM, XRD, Raman, elemental mapping and EDX analysis. The FeO NPs@rGOS modified GCE was developed for the determination of biomarker. Uric acid is important biomarker based on gout and kidney stone with high adverse effect in human body. The results obtained showed that the modified electrode FeO NPs@rGOS shows good electrochemical reduction peak compared to bare electrode and control electrodes. The FeO NPs@rGOS modified sensor linear range 0.02-783.6 µM was observed with nanomolar LOD 0.12 nM. In addition, the modified FeO NPs@rGOS/GCE sensor has been applied to determination of uric acid concentration in urine and blood serum samples. Furthermore, advantages of the modified sensor are high stability, repeatability and reproducibility.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultsonch.2019.104618DOI Listing

Publication Analysis

Top Keywords

feo nps@rgos
16
uric acid
12
feo
8
reduced graphene
8
graphene oxide
8
feo nps
8
nps@rgos modified
8
modified sensor
8
modified
5
novel sonochemical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!