Formulations that can increase the dissociation of insulin oligomers into monomers/dimers are important considerations in the development of ultra-rapid-acting insulins with faster onset and shorter duration of actions. Here we present a novel strategy to characterize the oligomeric states of insulin in solution that leverages the ability of nuclear magnetic resonance spectroscopy to assess higher-order structure of proteins in solution. The oligomeric structures and solution behaviors of 2 fast-acting insulins, aspart and lispro, with varying excipient concentrations were studied using 1D and diffusion profiling methods. These methods can provide insight on the structural differences and distributions of the molecular association states in different insulin formulations, which is consistent with other orthogonal biophysical characterization tools. In addition, these methods also highlight their sensitivity to subtle changes in solution behaviors in response to excipient that are difficult to monitor with other tools. This work introduces the utility of 1D and diffusion profiling methods to characterize the oligomeric assembly of fast-acting insulins, suggesting promising applications in compound screening, excipient selection, and formulation development of fast-acting insulins as well as other peptide or protein therapeutics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.xphs.2019.07.025 | DOI Listing |
Emerg Nurse
January 2025
Faculty of Health Education and Life Sciences, Birmingham City University, Birmingham, England.
Hypoglycaemia is a common cause of presentation to the emergency department (ED) for people with diabetes mellitus. Patients experiencing a hypoglycaemic episode require prompt treatment with fast-acting glucose to prevent brain fuel deprivation and functional brain failure, therefore it is vital that ED nurses can recognise the signs and symptoms of hypoglycaemia and are aware of the factors that can compound or mask it. This article discusses the aetiology and signs and symptoms of hypoglycaemia in adults with type 1 and type 2 diabetes and describes the use of an algorithm for the management of hypoglycaemia in this patient population in hospital.
View Article and Find Full Text PDFCureus
November 2024
Department of Pharmacology, Krishna Vishwa Vidyapeeth (Deemed to be University), Karad, IND.
Diabetes mellitus represents a significant and growing global health challenge, with its prevalence steadily increasing. Insulin therapy remains a cornerstone of diabetes management. Since its discovery in 1921, insulin has undergone substantial advancements, evolving from crude animal extracts to highly refined recombinant formulations and biosimilars.
View Article and Find Full Text PDFJ Clin Med
November 2024
Department of Endocrinology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Intermittent scanning continuous glucose monitoring (is-CGM) technology has gained widespread adoption and is known to improve glycemic control and quality of life for persons with diabetes. The elderly may lag behind in their adoption of the technology, which could be a potential avenue for improving quality of care. In this study, we investigated the adoption of is-CGM technology in the Dutch population, including effects of age.
View Article and Find Full Text PDFChemical probes have gained importance in the elucidation of signal transduction in biology. Insufficient selectivity and potency, lack of cellular activity and inappropriate use of chemical probes has major consequences on interpretation of biological results. The catalytic subunit of phosphoinositide 3-kinase α (PI3Kα) is one of the most frequently mutated genes in cancer, but fast-acting, high-quality probes to define PI3Kα's specific function to clearly separate it from other class I PI3K isoforms, are not available.
View Article and Find Full Text PDFEndocrine
October 2024
Emergency Department, Ng Teng Fong General Hospital, National University Health System, Singapore, Singapore.
Background: Diabetic ketoacidosis (DKA) is often treated with intravenous regular insulin infusion (IVRII). Subcutaneous fast-acting insulin analogues (FAIAs); either alone or combined with subcutaneous long-acting insulin (LAI); might be useful to treat DKA. Our meta-analysis updated on their benefits and safety in DKA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!