Aims: Transcatheter mitral valve replacement (TMVR) is a promising therapeutic solution to treat high-risk patients with severe mitral regurgitation (MR) contraindicated to surgery. Optimal selection of patients who will benefit from the procedure is of paramount importance. We aimed to investigate factors associated with TMVR screening.
Methods And Results: From November 2016 to July 2018, we examined conditions associated with TMVR screening success in patients referred to the two French heart valve clinics with the greatest TMVR experience. Among a total of 40 consecutively screened patients, 16 (40%) were selected for TMVR (8 Twelve Intrepid, 7 Tendyne and 1 HighLife), while 24 patients (60%) were refused for TMVR mainly because of a too large mitral annulus (MA) (n=15, 62% of those refused), or too small anatomy and risk of neo-left ventricular outflow tract (LVOT) obstruction (n=6, 25% of those refused). Patients with suitable anatomy for TMVR were more often male and more frequently suffered from secondary MR (p=0.01) associated with previous myocardial infarction and presented a commissure-to-commissure diameter less than 39 mm (AUC=0.72, p=0.0085) and LVESD greater than 32 mm (AUC=0.83, p<0.0001) on transthoracic echocardiography, and an MA area less than 17.6 cm² (AUC=0.95, p<0.0001) and anteroposterior diameter greater than 41.6 mm (AUC=0.87, p<0.001) on CT scan.
Conclusions: Despite several prostheses being available, most patients referred to heart valve clinics who are good candidates with regard to their clinical profile cannot have TMVR because of mismatch between their anatomy and prosthesis characteristics. Our findings suggest the need to develop new prostheses adapted to larger mitral annuli but with a lower impact on the LVOT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4244/EIJ-D-19-00444 | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Cardiology, Hospital of Lithuanian University of Health Sciences Kauno Klinikos, Lithuanian University of Health Sciences, 2 Eivenių Str., LT-50009 Kaunas, Lithuania.
: Transcatheter aortic valve implantation (TAVI) has emerged as a pivotal intervention for managing severe aortic stenosis in high-risk surgical patients. : This study aimed to evaluate the impacts of procedural factors and patient characteristics on TAVI outcomes, with a focus on survival rates, cardiac mortality, and associated complications. : A retrospective, single-center study involving 224 patients who underwent TAVI at the Lithuanian University of Health Sciences from September 2021 to April 2023 was conducted.
View Article and Find Full Text PDFAm J Cardiol
January 2025
Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA. Electronic address:
This study sought to explore the clinical factors associated with classical low-flow low-gradient (C-LFLG) and normal-flow low-gradient (NFLG) aortic stenosis (AS) compared to high-gradient (HG) AS. We also compared clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) across flow-gradient patterns. Patients with C-LFLG AS have a higher mortality rate after TAVR than those with HG AS.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
2nd Cardiology Department, Interbalkan Medical Center, 55535 Thessaloniki, Greece.
Background: Mitral regurgitation (MR) is a common valvular disorder linked to high morbidity and mortality. For patients unsuitable for surgery, transcatheter mitral edge-to-edge repair (TEER) with the MitraClip G4 system offers an alternative. This study aims to evaluate procedural, echocardiographic, functional, and quality of life (QoL) outcomes in patients who underwent TEER with the MitraClip G4 system, along with possible predictors of New York Heart Association (NYHA) class I at 30 days and at 1 year.
View Article and Find Full Text PDFInnovations (Phila)
January 2025
Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Objective: Percutaneous vegetation debulking has been reported to treat tricuspid valve infective endocarditis (TVIE), but data on feasibility compared with conventional surgical strategies are limited. We aimed to compare short-term outcomes of suction debulking with partial venovenous bypass to conventional open surgery in this population.
Methods: This was a single-center, retrospective study that included all patients with isolated TVIE who underwent suction debulking with partial venovenous bypass or tricuspid valve surgery between January 2010 and December 2022.
Cardiovasc Interv Ther
January 2025
Heart Valve Center, IRCCS San Raffaele, Milan, Italy.
Background: Treatment of residual mitral regurgitation (MR) with different percutaneous devices after transcatheter edge-to-edge repair (TEER) has been reported as an alternative option to reclipping or surgery. This review aims at describing the different transcatheter strategies available and their results when managing residual MR after TEER.