Background: Lone Bankart repair is associated with high rates of recurrence, especially in off-track Hill-Sachs (HS) lesion. The objective of the study was to assess the impact of remplissage in off-track HS lesion influencing the rate of redislocation and range of motion (ROM) of the shoulder.

Material And Method: We retrospectively reviewed 136 patients for arthroscopic Bankart repair without remplissage (group 1, n = 77) or with remplissage (group 2, n =59) for recurrent anterior dislocation of the shoulder with glenoid bone loss of <25%. Further subgroups of on- and off-track HS lesion were based on computed tomographic assessment. At a minimum follow-up of 2 years; patients were evaluated for functional scores (Rowe, Constant-Murley, Western Ontario Shoulder Instability Index), redislocations, and ROM.

Results: At a mean follow-up of 54 and 44 months in group 1 and 2, respectively, there was no difference in postoperative functional scores. There were significantly more dislocations in patients with Bankart repair with off-track lesion than in patients with Bankart repair with on-track lesion (P = .02). There were significantly fewer redislocations in patients with off-track lesion who underwent Bankart repair and remplissage than in those who did not undergo remplissage (P = .0007). Compared with group 1 patients, those in group 2 revealed a statistically significant loss of ROM.

Conclusions: Although a nonremplissaged off-track HS lesion remains an important risk factor for recurrent instability, remplissage also results in significant loss of shoulder ROM compared with those who do not undergo remplissage.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2019.06.005DOI Listing

Publication Analysis

Top Keywords

bankart repair
12
arthroscopic bankart
8
repair remplissage
8
off-track hill-sachs
8
hill-sachs lesion
8
range motion
8
remplissage group
8
retrospective cohort
4
cohort analysis
4
analysis arthroscopic
4

Similar Publications

Arthroscopic Bankart repair (ABR) is associated with an increased failure rate over time. The Recenter implant, a metal block, is designed to reinforce capsulolabral repair. The aim of this study was to evaluate whether the addition of the Recenter implant to ABR reduces the rate of recurrence in patients with glenohumeral anterior instability.

View Article and Find Full Text PDF

Objectives: Anterior shoulder instability with minimal glenoid bone loss has several options for Bankart repair. We aimed to evaluate the results of a modified technique using two anchors with double and single loaded suture (three stitches in total) in arthroscopic Bankart surgery.

Methods: Thirty-eight patients underwent arthroscopic Bankart surgery and were assessed after an average 40 months follow-up.

View Article and Find Full Text PDF

Background: Clinical studies have shown that the open Latarjet procedure (OLP) has lower recurrence rates than the isolated arthroscopic Bankart (IAB) procedure for recurrent anterior shoulder instability, but no long-term comparative studies exist for IAB in patients without bone loss.

Purpose/hypothesis: This study aimed to compare the outcomes of IAB in selected patients without bone loss versus OLP. The hypothesis was that OLP would be more successful in preventing recurrence, even in carefully selected patients for IAB.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!