Transcatheter aortic valve implantation has become an established procedure to treat severe aortic stenosis. Correct device sizing/positioning is crucial for optimal outcome. Lotus valve sizing is based upon multiple aortic root dimensions. Hence, it often occurs that two valve sizes can be selected. In this study, patient-specific computer simulation is adopted to evaluate the influence of Lotus size/position on paravalvular aortic regurgitation (AR) and conduction abnormalities, in patients with equivocal aortic root dimensions. First, simulation was performed in 62 patients to validate the model in terms of predicted AR and conduction abnormalities using postoperative echocardiographic, angiographic and ECG-based data. Then, two Lotus sizes were simulated at two positions in patients with equivocal aortic root dimensions. Large valve size and deep position were associated with higher contact pressure, while only large size, not position, significantly reduced the predicted AR. Despite general trends, simulations revealed that optimal device size/position is patient-specific.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12265-019-09877-2 | DOI Listing |
BMC Cardiovasc Disord
January 2025
Department of Thoracic and Cardiovascular Surgery, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.
Background: The aim of this study was to investigate whether the hybrid technique yields superior outcomes in comparison with the total arch replacement combined with frozen elephant trunk (TAR + FET) for acute aortic dissection (AAD) involving the aortic arch.
Methods: This retrospective cohort study using propensity-score matching included patients with AAD involving the aortic arch admitted to Nanjing First Hospital and Shanghai General Hospital from January 2015 to June 2020. The in-hospital and mid-term outcomes were compared between patients who received hybrid treatment (n = 136) and those who received TAR + FET (n = 415).
Comput Biol Med
January 2025
LaBS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy. Electronic address:
In the context of dynamic image-based computational fluid dynamics (DIB-CFD) modeling of cardiac system, the role of sub-valvular apparatus (chordae tendineae and papillary muscles) and the effects of different mitral valve (MV) opening/closure dynamics, have not been systemically determined. To provide a partial filling of this gap, in this study we performed DIB-CFD numerical experiments in the left ventricle, left atrium and aortic root, with the aim of highlighting the influence on the numerical results of two specific modeling scenarios: (i) the presence of the sub-valvular apparatus, consisting of chordae tendineae and papillary muscles; (ii) different MV dynamics models accounting for different use of leaflet reconstruction from imaging. This is performed for one healthy subject and one patient with mitral valve regurgitation.
View Article and Find Full Text PDFCardiovasc Toxicol
January 2025
Department of Cadre Ward, The First Affiliated Hospital of Harbin Medical University, No. 23, Postal Street, Harbin, 150001, Heilongjiang, PR China.
Atherosclerosis risk is elevated in diabetic patients, but the underlying mechanism such as the involvement of macrophages remains unclear. Here, we investigated the underlying mechanism related to the pro-inflammatory activation of macrophages in the development of diabetic atherosclerosis. Bioinformatics tools were used to analyze the macrophage-related transcriptome differences in patients with atherosclerosis and diabetic mice.
View Article and Find Full Text PDFSci Rep
January 2025
University of Ulsan, 93 Daehak-ro, Nam-gu, Ulsan, 680-749, Republic of Korea.
This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Division of Vascular Surgery, University of Maryland, Baltimore, Maryland.
Background: Thoracic Endovascular Aortic Repair (TEVAR) reduced mortality for blunt aortic injury (BAI) from 30-50% to < 10%; however, penetrating traumatic aortic injury (PAI) remains highly lethal (>40% mortality). This study's goal is to determine outcomes of TEVAR for PAI.
Methods: Patients undergoing TEVAR for traumatic aortic injuries were identified from the Vascular Quality Initiative database from 2011-2022.