Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Operando laboratory X-ray radiographies were carried out for imaging of two different silver-based gas diffusion electrodes containing an electroconductive Ni mesh structure, one gas diffusion electrode composed of 95 wt.% Ag and 5 wt.% polytetrafluoroethylene and one composed of 97 wt.% Ag and 3 wt.% polytetrafluoroethylene, under different operating parameters. Thereby, correlations of their electrochemical behavior and the transport of the 30 wt.% NaOH electrolyte through the gas diffusion electrodes were revealed. The work was divided into two parts. In the first step, the microstructure of the gas diffusion electrodes was analyzed ex situ by a combination of focused ion beam technology and synchrotron as well as laboratory X-ray tomography and radiography. In the second step, operando laboratory X-ray radiographies were performed during chronoamperometric measurements at different potentials. The combination of the ex situ microstructural analyses and the operando measurements reveals the impact of the microstructure on the electrolyte transport through the gas diffusion electrodes. Hence, an impact of the Ni mesh structure within the gas diffusion electrode on the droplet formation could be shown. Moreover, it could be observed that increasing overpotentials cause increasing electrolyte transport velocities and faster droplet formation due to electrowetting. In general, higher electrolyte transport velocities were found for the gas diffusion electrode with 97 wt.% Ag in contrast to that with 95 wt.% Ag.