Background And Aims: Currently available peroral cholangioscopy (POC) is a duodenoscopy-assisted procedure that does not involve directly inserting an endoscope into the biliary tree. A prototype multibending (MB) ultra-slim endoscope has been developed as a dedicated cholangioscope to overcome the technical difficulties of direct POC. In this study, we evaluated the efficacy of the new MB ultra-slim endoscope compared with a conventional ultra-slim endoscope for free-hand insertion of an endoscope into the bile duct for direct POC without the assistance of accessories.
Methods: Ninety-two patients with biliary disease requiring diagnostic and/or therapeutic direct POC were assigned randomly to groups examined using an MB ultra-slim endoscope (MB group, n=46) versus a conventional ultra-slim endoscope (conventional group, n=46). The primary outcome was the technical success of free-hand insertion of the endoscope during direct POC, defined as successful insertion of the endoscope through the ampulla of Vater and advancement of the endoscope up to the bifurcation or to the obstructed segment of the biliary tree without any accessories within 15 minutes.
Results: Free-hand biliary insertion of the endoscope for direct POC was technically successful in 41 patients (89.1%) in the MB group, which was significantly higher than the rate (14 patients, 30.4%) in the conventional group (P < .001). The procedure time (mean ± standard deviation) of direct POC using free-hand biliary insertion of the endoscope was significantly shorter in the MB group than in the conventional group (3.2 ± 1.8 vs 6.0 ± 3.0 minutes, P = .004). Adverse events were observed in 3 patients (6.5%) in the MB group and 2 patients (4.3%) in the conventional group (P = .500), all of whom were treated conservatively. The technical success rates of the diagnostic or therapeutic intervention were not significantly different between the 2 groups in patients undergoing successful direct POC.
Conclusions: Free-hand biliary insertion of the MB ultra-slim endoscope showed a high technical success rate without severe adverse events and effectively decreased procedure time compared with a conventional ultra-slim endoscope. Direct POC using the MB ultra-slim endoscope can be used for novel diagnostic and therapeutic procedures of the biliary tree without the assistance of another endoscope or accessory. (Clinical trial registration number: NCT02189421.).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gie.2019.08.007 | DOI Listing |
Introduction: Lymphocytic esophagitis (LyE) is a rare esophageal disorder of unknown etiology, characterized by dense peripapillary lymphocytes without neutrophils or eosinophils, and spongiosis. Patients typically present with symptoms such as dysphagia or chest pain. Here, we describe a notable case of lymphocytic esophagitis in a patient who presented with food impaction.
View Article and Find Full Text PDFGastrointest Endosc
September 2024
Department of Gastroenterology and Hepatology, Okayama University Hospital, Okayama, Japan.
Background And Aims: The difficulty in radiographic confirmation of the presence of stones remains challenging in the treatment of intrahepatic bile duct (IHBD) stones in patients after hepaticojejunostomy (HJ). Peroral direct cholangioscopy (PDCS) enables direct observation of the bile duct and is useful for detecting and removing residual stones; however, its effectiveness is not clearly established in this clinical context.
Methods: This single-center, single-arm, prospective study included 44 patients with IHBD who underwent bowel reconstruction with HJ during the study period.
Intern Med
December 2024
Department of Gastroenterology, Kobe City Medical Center General Hospital, Japan.
JPGN Rep
February 2024
Center for Digestive Health and Nutrition Arnold Palmer Hospital for Children, Orlando Health Orlando Florida USA.
Introduction: Unsedated transnasal endoscopy (TNE) as transnasal esophagoscopy (TN-Eso) has emerged as a promising alternative to esophagogastroduodenoscopy (EGD) under sedation to assess eosinophilic esophagitis (EoE). We report our center's experience using single-use gastroscopes to perform sedation-free transnasal EGD (TN-EGD) with biopsies in an office-based setting.
Methods: A retrospective review was performed on patients with eosinophilic esophagitis who underwent office-based sedation-free TNE with topical analgesia and virtual reality (VR) procedural dissociation and distraction.
Endosc Int Open
March 2024
Department of Gastroenterology and Hepatology, Erasmus MC, Rotterdam, Netherlands.
Reprocessing reusable endoscopes is challenging due to their non-sterilizable nature. Disinfection has been shown to have a significant risk of failure with serious consequences. Single-use endoscopes can eliminate contamination risk and reduce workflow delays caused by reprocessing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!