Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To evaluate the biological and mechanical complications of angulated abutments on full-arch and partial jaw rehabilitations with a follow-up for at least 1 year.
Methods: Electronic search was carried out in MEDLINE, EMBASE and Web of Science. Studies published between January 2000 and January 2019 were included. The quality of the included studies was assessed. The data extraction was focused on implant loss, marginal bone loss and mechanical complications, and meta-analyses were performed for marginal bone loss, mechanical complications and implant failure.
Results: Nine studies, three prospective and six retrospective cohort studies were included. They reported on 797 patients that received 4127 implants. The total number of abutments was 4079 of which 1673 were angulated, and 2406 were straight. All abutments were prefabricated. Angulated abutments were associated with increased implant failure rates (two studies; RR = 7.30; 95% CI = 2.79-19.08) and an effect that was both statistically significant (P < .001) and clinically relevant. Three studies reported differentiated data for mechanical and technical complications at 1 year of follow-up, being mostly related to the retention screw while screw fracture. Angulated abutments were associated with a statistically significant increase in MBL 1 year after insertion compared to straight abutments (three studies; MD = 0.08 mm; 95% CI = 0.01-0.14 mm; P = .02), which might be, however, clinically negligible.
Conclusions: The prosthetic complications such as screw loosening and abutment loosening were frequent. After 1 year of follow-up, implants supporting angulated abutments yielded significantly more marginal bone loss than those supporting straight abutments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/joor.12877 | DOI Listing |