The dual-energy computed tomography (DECT)-based approach holds promise in reducing the overall uncertainty in proton stopping-power-ratio (SPR) estimation, but cannot be easily implemented with most commercial proton treatment planning systems (TPS). In this study, we revisited the idea of coupling the stoichiometric calibration method with virtual monoenergetic CT datasets (MonoCT) generated by modern DECT scanners, because of its readiness for implementation with the existing TPS. Our objective was to determine the optimal energy of the MonoCT dataset for stoichiometric calibration and estimate the overall uncertainty in SPR estimation at the optimal energy. We performed stoichiometric calibration for MonoCT datasets across the energy range available on a Siemens Force DECT scanner and a Philips IQon DECT scanner in a 10 keV step. We estimated the uncertainties of different sources (imaging, modeling, and inherent uncertainties) for different tissue types (lung, soft, and bone tissues) associated with each energy; these were then combined into a single composite uncertainty for three tumor sites (head-and-neck (HN), lung, and prostate). The optimal energy was eventually selected based on the composite range uncertainty, which turned out to be 160 keV for both DECT scanners. At 160 keV, the total uncertainties (2σ) in SPR estimation were determined to be 3.2%-4.5%, 0.9%, and 1.4%-1.6% for lung, soft, and bony tissues, respectively. These results were comparable to the corresponding values estimated for the DECT approach evaluated in our previous study: 3.8%, 1.2% and 2.0%, for lung, soft, and bony tissues, respectively. The composite range uncertainties (2σ) were estimated as 1.5%, 1.7%, and 1.5% for prostate, lung, and HN, respectively. Our results demonstrated the potential of MonoCT images for reducing proton SPR uncertainty. Further clinical studies are needed to compare this approach with the DECT approach directly on real patient cases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ab3dec | DOI Listing |
J Exp Bot
January 2025
National Institute of Science and Technology on Plant Physiology under Stress Conditions, Departamento de Biologia Vegetal, Universidade Federal de Viçosa, Viçosa 36570-900, Minas Gerais, Brazil.
The transport of metabolites across the inner mitochondrial membrane (IMM) is crucial for maintaining energy balance and efficient distribution of metabolic intermediates between cellular compartments. Under abiotic stress, mitochondrial function becomes particularly critical, activating complex signaling pathways essential for plant stress responses. These pathways modulate stress-responsive gene expression, influencing key physiological processes such as cell respiration and senescence, helping plants adapt to stress.
View Article and Find Full Text PDFAcc Chem Res
January 2025
Helmholtz Institute Ulm (HIU) Electrochemical Energy Storage, Helmholtzstrasse 11, 89081 Ulm, Germany.
ConspectusLithium-ion batteries (LIBs) based on graphite anodes are a widely used state-of-the-art battery technology, but their energy density is approaching theoretical limits, prompting interest in lithium-metal batteries (LMBs) that can achieve higher energy density. In addition, the limited availability of lithium reserves raises supply concerns; therefore, research on postlithium metal batteries is underway. A major issue with these metal anodes, including lithium, is dendritic formation and insufficient reversibility, which leads to safety risks due to short circuits and the use of flammable electrolytes.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Pharmaceutical Chemistry, Semmelweis University, Hőgyes Endre U. 9, 1092, Budapest, Hungary.
Microtiter-plate-based systems are unified platforms of high-throughput experimentation (HTE). These polymeric devices are used worldwide on a daily basis-mainly in the pharmaceutical industry-for parallel syntheses, reaction optimization, various preclinical studies and high-throughput screening methods. Accordingly, laboratory automation today aims to handle these commercially available multiwell plates, making developments focused on their modifications a priority area of modern applied research.
View Article and Find Full Text PDFRadiol Clin North Am
March 2025
Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA; Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA.
Imaging is essential in the evaluation and management of acute pulmonary embolism. Advances in multi-energy CT including dual-energy CT and photon-counting CT have allowed faster scans with lower radiation dose and optimal quality. Artificial intelligence has a potential role in triaging potentially positive examinations and could serve as a second reader.
View Article and Find Full Text PDFKidney Int
January 2025
Néphrologie et Dialyse, Centre Hospitalier Le Mans, 194 Avenue Rubillard, 72037 Le Mans, France.
Kidney replacement therapy (KRT) is one of the most energy-consuming and waste-producing medical treatments. Reducing the need of dialysis is therefore an environmentally friendly choice. However, preferring prevention, lifestyle-related interventions and patient education to drugs is time consuming and most physicians are already overburdened by the many demands of routine clinical practice.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!