A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical Note: Characterization of x-ray beam profiles for a fluoroscopic system incorporating copper filtration. | LitMetric

Purpose: The goal of this study was to investigate x-ray beam profiles at various water depths to characterize the two-dimensional x-ray dose distribution, allowing for off-axis and out-of-field radiation dose estimation for a wide range of x-ray beam spectra commonly encountered in fluoroscopically guided interventional procedures.

Methods: A Siemens Artis interventional fluoroscope was operated in a service mode to generate a continuous x-ray beam at fixed x-ray beam spectra, defined by their kVp and the thickness of additional copper filtration. A PTW scanning water tank with a diode detector was used to measure the x-ray beam profiles at several depths in water at various fields of view and x-ray beam spectra, both parallel and perpendicular to the anode-cathode axis direction.

Results: X-ray beam profiles, including out-of-field tails, were characterized for a wide range of beam qualities. The anode heel effect was pronounced even at depth, resulting in large dose variations across the x-ray field; this effect was even more definite at large fields of view, at higher kVps, and in the absence of additional copper filtration.

Conclusions: This study investigated and characterized 2D radiation dose deposition in water from x-ray beam spectra commonly used by modern fluoroscopes in interventional procedures. This knowledge can be applied to manual dosimetry calculations or can be used to refine the accuracy of automated dose mapping tools or Monte Carlo simulations of the radiation dose to soft tissue within the x-ray field and to tissue adjacent to the primary beam. Additionally, this study illustrates a substantial reduction of the anode heel effect by using moderate amounts of additional copper filtration to harden the x-ray beam spectrum.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13774DOI Listing

Publication Analysis

Top Keywords

x-ray beam
40
beam profiles
16
beam spectra
16
x-ray
13
beam
12
copper filtration
12
radiation dose
12
additional copper
12
wide range
8
spectra commonly
8