Background: Maximizing extent of resection (EOR) and reducing residual tumor volume (RTV) while preserving neurological functions is the main goal in the surgical treatment of gliomas. Navigated intraoperative ultrasound (N-ioUS) combining the advantages of ultrasound and conventional neuronavigation (NN) allows for overcoming the limitations of the latter.

Objective: To evaluate the impact of real-time NN combining ioUS and preoperative magnetic resonance imaging (MRI) on maximizing EOR in glioma surgery compared to standard NN.

Methods: We retrospectively reviewed a series of 60 cases operated on for supratentorial gliomas: 31 operated under the guidance of N-ioUS and 29 resected with standard NN. Age, location of the tumor, pre- and postoperative Karnofsky Performance Status (KPS), EOR, RTV, and, if any, postoperative complications were evaluated.

Results: The rate of gross total resection (GTR) in NN group was 44.8% vs 61.2% in N-ioUS group. The rate of RTV > 1 cm3 for glioblastomas was significantly lower for the N-ioUS group (P < .01). In 13/31 (42%), RTV was detected at the end of surgery with N-ioUS. In 8 of 13 cases, (25.8% of the cohort) surgeons continued with the operation until complete resection. Specificity was greater in N-ioUS (42% vs 31%) and negative predictive value (73% vs 54%). At discharge, the difference between pre- and postoperative KPS was significantly higher for the N-ioUS (P < .01).

Conclusion: The use of an N-ioUS-based real-time has been beneficial for resection in noneloquent high-grade glioma in terms of both EOR and neurological outcome, compared to standard NN. N-ioUS has proven usefulness in detecting RTV > 1 cm3.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ons/opz203DOI Listing

Publication Analysis

Top Keywords

navigated intraoperative
8
glioma surgery
8
extent resection
8
n-ious group
8
intraoperative 2-dimensional
4
2-dimensional ultrasound
4
ultrasound high-grade
4
high-grade glioma
4
surgery impact
4
impact extent
4

Similar Publications

Mixed reality for preoperative planning and intraoperative assistance of surgical correction of complex congenital heart defects.

J Thorac Cardiovasc Surg

January 2025

Division of Cardiology, The Hospital for Sick Children, Toronto, ON, Canada; Center for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, ON, Canada.

Objectives: Mixed reality (MixR) is an innovative visualization tool that presents virtual elements in a real-world environment, enabling real-time interaction between the user and the combined digital/physical reality. We aimed to explore the feasibility of MixR in enhancing preoperative planning and intraoperative guidance for the correction of various complex congenital heart defects (CHDs).

Methods: Patients underwent cardiac computed tomography or cardiac magnetic resonance and segmentation of digital imaging and communications in medicine (DICOM) images was performed.

View Article and Find Full Text PDF

Placenta accreta spectrum (PAS) poses a significant risk for maternal morbidity and mortality. There is a global rise in incidence of PAS in tandem with an increase in rates of cesarian section. Previous cesarian section and presence of placenta previa are two independent risk factors for development of PAS.

View Article and Find Full Text PDF

Kissing aneurysms, a rare and intriguing cerebrovascular anomaly, challenge even the most advanced neurosurgical techniques. These lesions, characterized by two intimately apposed aneurysms with shared arterial walls, often masquerade as single, irregular aneurysms. This report documents a case of ruptured kissing aneurysms in the M1 segment of the right middle cerebral artery (MCA), complicated by ischemic stroke and pulmonary thromboembolism (PTE)-a convergence of severe complications rarely encountered.

View Article and Find Full Text PDF

: Surgical accuracy in total knee replacement (TKR) may vary with the surgeon, the patient preoperative deformity, and the guiding system to perform the procedure. Navigation systems attempt to increase the intraoperative information the surgeon requires to make the appropriate decisions, sometimes associating cumbersome procedures and unclear effectiveness to place the implant more precisely than conventional instruments. : We conducted a retrospective case-control study with prospective data collection of radiographic measurements (alignment, joint line and patellar height) in a sample of 100 consecutive patients receiving TKR Optetrak Logic PS, either with standard surgical technique with Trulion Instrumentation ( = 59) or with the Guided Personalized Surgery (GPS) system ( = 41).

View Article and Find Full Text PDF

This study evaluates the feasibility of Apple Vision Pro goggles as an augmented reality (AR) surgical navigation tool for laparoscopic-assisted ultrasound-guided radiofrequency ablation (RFA) of liver tumors. Traditional RFA is effective but challenging due to the integration of multiple imaging modalities. The primary aim of this research is to assess how Vision Pro goggles can enhance the surgical navigation process during RFA, improving tumor localization and the overall effectiveness of the procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!