Purpose: To Compare the extent and intensity of adhesions formed between the intra-abdominal organs and the intraperitoneal implants of polypropylene mesh versus polypropylene/polyglecaprone versus polyester/porcine collagen used for correction of abdominal wall defect in rats.
Methods: After the defect in the abdominal wall, thirty Wistar rats were placed in three groups (ten animals each) for intraperitoneal mesh implant: polypropylene group, polypropylene/polyglecaprone group, and polyester/porcine collagen group. The macroscopic evaluation of the extent and intensity of adhesions was performed 21 days after the implant.
Results: The polypropylene group had a higher statistically significant impairment due to visceral adhesions (p value = 0.002) and a higher degree of intense adherence in relation to polypropylene/polyglecaprone and polyester/porcine collagen groups (p value<0.001). The polyester/porcine collagen group showed more intense adhesions than the polypropylene/polyglecaprone group (p value=0.035).
Conclusions: The intraperitoneal implantation of polypropylene meshes to correct defects of the abdominal wall caused the appearance of extensive and firm adhesions to intra-abdominal structures. The use of polypropylene/polyglecaprone or polyester/porcine collagen tissue-separating meshes reduces the number and degree of adhesions formed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6705338 | PMC |
http://dx.doi.org/10.1590/s0102-865020190060000003 | DOI Listing |
Acta Cir Bras
September 2021
PhD, Associate Professor - Department General Surgery - Faculty of Medical Sciences - Universidade do Estado do Rio de Janeiro (UERJ) - Rio de Janeiro (RJ), Brazil.
Purpose: To compare tissue inflammatory response, foreign body reaction, fibroplasia, and proportion of type I/III collagen between closure of abdominal wall aponeurosis using polyglactin suture and intraperitoneal implant of polypropylene, polypropylene/polyglecaprone, and polyester/porcine collagen meshes to repair defects in the abdominal wall of rats.
Methods: Forty Wistar rats were placed in four groups, ten animals each, for the intraperitoneal implant of polypropylene, polypropylene/polyglecaprone, and polyester/porcine collagen meshes or suture with polyglactin (sham) after creation of defect in the abdominal wall. Twenty-one days later, histological analysis was performed after staining with hematoxylin-eosin and picrosirius red.
Acta Cir Bras
August 2019
PhD, Associate Professor, Department of General Surgery, Faculty of Medical Sciences, UERJ, Rio de Janeiro-RJ, Brazil. Conception and design of the study, interpretation and analysis of data, critical revision, final approval.
Purpose: To Compare the extent and intensity of adhesions formed between the intra-abdominal organs and the intraperitoneal implants of polypropylene mesh versus polypropylene/polyglecaprone versus polyester/porcine collagen used for correction of abdominal wall defect in rats.
Methods: After the defect in the abdominal wall, thirty Wistar rats were placed in three groups (ten animals each) for intraperitoneal mesh implant: polypropylene group, polypropylene/polyglecaprone group, and polyester/porcine collagen group. The macroscopic evaluation of the extent and intensity of adhesions was performed 21 days after the implant.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!