In this work, we report a new design of a charge detection quadrupole ion trap mass spectrometer (QIT-MS) for the analysis of micro-sized dry inorganic and bioparticles including red blood cells (RBCs) and different sizes of MCF-7 breast cancer cells. The developed method is one of the fastest methods to measure the mass of micro-sized particles. This system allows the online analysis of various micro-sized particles up to 1 × 10 Da. The calibration of the mass spectrometer has been done by using different sizes of polystyrene (PS) particles (2-15 μm). The measured masses of RBCs were around 1.8 × 10 Da and MCF-7 cancer cells were between 1 × 10 and 4 × 10 Da. The calculated mass distribution profiles of the particles and cells were given as histogram profiles. The statistical data were summarized after Gaussian type fitting to the experimental histogram profiles. The new method gives very promising results for the analysis of particles and has very broad application.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c9an01431dDOI Listing

Publication Analysis

Top Keywords

mass spectrometer
12
quadrupole ion
8
ion trap
8
trap mass
8
analysis micro-sized
8
cancer cells
8
micro-sized particles
8
histogram profiles
8
mass
5
particles
5

Similar Publications

Background/objectives: This study investigates the metabolic profile of a single dose of etodolac in healthy volunteers, focusing on pharmacokinetics, clinical parameters, and metabolomic variations to identify biomarkers and pathways linked to drug response, efficacy, and safety.

Methods: Thirty-seven healthy volunteers, enrolled after rigorous health assessments, received a single dose of etodolac (Flancox 500 mg). Pharmacokinetic profiles were determined using tandem mass spectrometry analysis, and the metabolomic profiling was conducted using baseline samples (pre-dose) and samples at maximum drug concentration (post-dose) via liquid chromatography coupled with a quadrupole time-of-flight mass spectrometer.

View Article and Find Full Text PDF

A covalent organic framework (COF) has emerged as a promising photocatalyst for the removal of pharmaceutical and personal care product (PPCP) contaminants; however, high-performance COF photocatalysts are still scarce. In this study, three COF photocatalysts were successfully synthesized by the condensation of benzo[1,2-b:3,4-b':5,6-b'']trithiophene-2,5,8-tricarbaldehyde (BTT) with 4,4',4''-(1,3,5-triazine-2,4,6-triyl)trianiline (TAPT), 1,3,5-Tris(4-aminophenyl)benzene (TAPB), and 4,4',4''-nitrilotris(benzenamine) (TAPA), namely, BTT-TAPA, BTT-TAPB, and BTT-TAPT, respectively. The surface areas of BTT-TAPA, BTT-TAPB, and BTT-TAPT were found to be 800.

View Article and Find Full Text PDF

Background: X-linked hypophosphatemia (XLH) is a rare disorder characterized by elevated levels of fibroblast growth factor 23 (FGF-23), leading to hypophosphatemia and complications in diagnosis due to its clinical heterogeneity. Metabolomic analysis, which examines metabolites as the final products of cellular processes, is a powerful tool for identifying in vivo biochemical changes, serving as biomarkers of pathological abnormalities, and revealing previously uncharted metabolic pathways.

Methods: A multicenter cross-sectional case-control study of adult patients diagnosed with XLH was conducted.

View Article and Find Full Text PDF

A water-soluble polysaccharide from foxtail millet (FM-D1) was isolated and purified through gradient ethanol precipitation and column chromatography. Size-Exclusion Chromatography-Multi-Angle Light Scattering-Refractive Index (SEC-MALLS-RI) and high-performance anion-exchange chromatography (HPAEC) analyses revealed that FM-D1 constitutes a highly purified neutral polysaccharide exclusively composed of glucose as the sugar unit, with a molecular weight of 14.823 kDa.

View Article and Find Full Text PDF

Data-independent acquisition (DIA) on ion mobility mass spectrometers enables deep proteome coverage and high data completeness in large-scale proteomics studies. For advanced acquisition schemes such as parallel accumulation serial fragmentation-based DIA (diaPASEF) stability of ion mobility (1/K) over time is crucial for consistent data quality. We found that minor changes in environmental air pressure systematically affect the vacuum pressure in the TIMS analyzer, causing ion mobility shifts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!