Background And Purpose: Anatomical changes induce differences between planned and delivered dose. Adaptive radiotherapy (ART) may reduce these differences but the optimal implementation is insufficiently clear. The aims of this study were to quantify the difference between planned and delivered dose in HNC patients, assess the consequential difference in normal tissue complication probability (ΔNTCP) and to explore the value of ΔNTCP as an objective selection strategy for ART.

Materials And Methods: For 52 patients, daily doses were accumulated to estimate the delivered dose. The difference from planned dose was analyzed for CTVs and 9 organs-at-risk (OAR). ΔNTCP was calculated for xerostomia, dysphagia, parotid gland dysfunction and tube feeding dependency at 6 months. ART was deemed necessary if ΔNTCP was >5%. The positive predicted value (PPV) was calculated for identification of ART-patients by clinical judgement, and ΔNTCP at fraction 10 and 15.

Results: ΔNTCP >5% was seen five times for dysphagia and twice for the other toxicities. Only 5/9 patients with any ΔNTCP >5% clinically received ART, although ART had been done for 13/52 patients (PPV: 0.38). PPV was 0.86 and 0.75 for accumulated dose at fraction 10 and 15, respectively, using a ΔNTCP cut-off for the allocation of ART of 5%. Using other ΔNTCP cut-offs did not substantially improve PPV. With this cut-off the negative predictive value was 0.93 for ΔNTCP method of fraction 10 and fraction 15, and 0.90 for clinical judgement.

Conclusion: To identify patients accurately for ART, NTCP calculations based on the dose differences between planned and delivered dose at fraction 10 are superior to clinical judgement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7401328PMC
http://dx.doi.org/10.1016/j.radonc.2019.07.034DOI Listing

Publication Analysis

Top Keywords

delivered dose
20
planned delivered
16
differences planned
12
Δntcp >5%
12
Δntcp
10
dose
8
normal tissue
8
tissue complication
8
complication probability
8
difference planned
8

Similar Publications

Self-supervised denoising of grating-based phase-contrast computed tomography.

Sci Rep

December 2024

Research Group Biomedical Imaging Physics, Department of Physics, TUM School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.

In the last decade, grating-based phase-contrast computed tomography (gbPC-CT) has received growing interest. It provides additional information about the refractive index decrement in the sample. This signal shows an increased soft-tissue contrast.

View Article and Find Full Text PDF

Background/aim: This study aimed to predict the optimal timing for adaptive radiation therapy (ART) using two-dimensional X-ray image-based water equivalent thickness (2DWET).

Patients And Methods: Forty patients with oropharyngeal and hypopharyngeal cancer underwent Computed Tomography (CT) rescanning during treatment. An adaptive score (AS) was proposed to guide ART decisions based on changes in four dose indices: target coverage, spinal cord dose, parotid gland dose, and over-dose volume.

View Article and Find Full Text PDF

Targeted Radionuclide Therapy Activates Prodrugs for Treating Metastasis.

ACS Cent Sci

December 2024

Beijing National Laboratory for Molecular Sciences, Radiochemistry and Radiation Chemistry Key Laboratory of Fundamental Science, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.

Over 90% of cancer patients succumb to metastasis, yet conventional frontline therapy struggles to halt the progression of metastatic tumors. Targeted radionuclide therapy, which delivers radiation precisely to tumor sites, shows promise for treating metastasis. The rational design of a prodrug activation platform using radionuclides would be an ideal approach to synergize chemotherapy with targeted radionuclide therapy, yet it has not been established.

View Article and Find Full Text PDF

Preinduction cervical ripening in previous caesarean pregnancy is limited to intracervical Foley catheter. This study is aimed at finding the vaginal birth rates, improvement of Bishop score, and safety of osmotic dilator (Dilapan-S) among women with previous caesarean pregnancy. We conducted this single-group clinical study after the approval of the institute ethics committee, clinical trial registration, and obtaining informed consent.

View Article and Find Full Text PDF

Development and external validation of a multi-task feature fusion network for CTV segmentation in cervical cancer radiotherapy.

Radiother Oncol

December 2024

Department of Digital Medicine, School of Biomedical Engineering and Medical Imaging, Army Medical University, Chongqing 400038, China. Electronic address:

Background And Purpose: Accurate segmentation of the clinical target volume (CTV) is essential to deliver an effective radiation dose to tumor tissues in cervical cancer radiotherapy. Also, although automated CTV segmentation can reduce oncologists' workload, challenges persist due to the microscopic spread of tumor cells undetectable in CT imaging, low-intensity contrast between organs, and inter-observer variability. This study aims to develop and validate a multi-task feature fusion network (MTF-Net) that uses distance-based information to enhance CTV segmentation accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!