Background: When a water pipe breaks, contaminants can enter the drinking water system and cause waterborne illnesses such as acute gastrointestinal illness. In May 2010, a major water pipe broke near Boston, MA, and a boil water order was issued to nearly two million residents.
Methods: Using a case-crossover study design, we examined the association between the water pipe break and subsequent emergency department visits for acute gastrointestinal illness. We identified cases of illness according to ICD-9-CM diagnosis codes and selected control dates 2 weeks before and after each case. We estimated the risk of visiting the emergency department during the 0-3 and 4-7 days after the water pipe break using conditional logistic regression models.
Results: Our analysis included 5,726 emergency department visits for acute gastrointestinal illness from 3 April 2010 to 5 June 2010. Overall, there was a 1.3-fold increased odds for visiting the emergency department for acute gastrointestinal illness during the 0-3 days after the water pipe break (odds ratio [OR] = 1.3; 95% confidence interval [CI] = 1.1, 1.4) compared with referent dates selected 2 weeks before and after. During the 4-7 days after the break, the association diminished overall (OR = 1.1; 95% CI = 0.96, 1.2). However, in communities over 12 miles from the break, the 4- to 7-day association was elevated (OR = 1.4; 95% CI = 1.1, 1.8).
Conclusions: This study suggests that a major water pipe break was associated with emergency department visits for acute gastrointestinal illness, particularly during the 0-3 days after the break, when a boil water order was in effect.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10615350 | PMC |
http://dx.doi.org/10.1097/EDE.0000000000001083 | DOI Listing |
Sensors (Basel)
January 2025
State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering, Nanjing Hydraulic Research Institute, Nanjing 210029, China.
Water pipelines in water diversion projects can leak, leading to soil deformation and ground subsidence, necessitating research into soil deformation monitoring technology. This study conducted model tests to monitor soil deformation around leaking buried water pipelines using distributed fiber optic strain sensing (DFOSS) technology based on optical frequency domain reflectometry (OFDR). By arranging strain measurement fibers in a pipe-soil model, we investigated how leak location, leak size, pipe burial depth, and water flow velocity affect soil strain field monitoring results.
View Article and Find Full Text PDFJ Environ Manage
January 2025
Civil, Construction and Environmental Engineering, Marquette University, 1637 W. Wisconsin Ave, Milwaukee, WI, USA. Electronic address:
Green stormwater infrastructure is growing in adoption across the world due to its ability to capture and treat stormwater runoff at the source; however, while green stormwater infrastructure is effective at reducing the concentration of many priority pollutants, bioretention often increases the concentration of dissolved phosphorus in the stormwater it treats. This is a significant shortcoming, as dissolved phosphorus can promote algae growth in receiving water bodies resulting in negative impacts to human and aquatic health. This study seeks to address this shortcoming through an end-of-pipe filter at the end of bioretention effluent pipes designed to reduce the concentration of dissolved phosphorus.
View Article and Find Full Text PDFVet Sci
January 2025
Department of Veterinary Sciences, University of Pisa, 56124 Pisa, Italy.
The impact of enrichment on stress reduction in zebrafish () exposed to a novel environment was assessed. Four control shoals (CTRL) and five treated shoals (TRT), each with eight fish, were observed; in TRT tanks, a PVC pipe was included (three-way tube, 11.7 × 4 cm) as enrichment for 90 days.
View Article and Find Full Text PDFEnviron Sci Technol
January 2025
Department of Aquatic Sciences and Assessment, Swedish University of Agricultural Sciences, Uppsala 75651, Sweden.
Per- and polyfluoroalkyl substances (PFAS)-containing firefighting foam have been used in stationary fire suppression systems for several decades. However, there is a lack of research on how to decontaminate PFAS-contaminated infrastructure and evaluate treatment efficiency. This study assessed the removal of PFAS from stainless steel pipe surfaces using different cleaning agents (tap water, methanol, and aqueous solutions containing 10 and 20 wt % of butyl carbitol (BC)) at different temperatures (20 °C, 40 °C, and 70 °C).
View Article and Find Full Text PDFSci Total Environ
January 2025
The University of Yaoundé I, National Advanced School of Engineering of Yaoundé, P.O. Box: 8390, Yaoundé, Cameroon. Electronic address:
Carbon dioxide (CO) accumulation and emission are well-known features of deep lakes, making them a significant unavoidable carbon source to the atmosphere. In the case of meromictic lakes, degassing devices are installed to controllably release through a pipe the CO trapped in the bottom waters. Otherwise, the gas is emitted diffusely at the air-water surface or accidentally through a limnic eruption when the saturation limit is reached.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!