A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

3D Imaging of Nanoparticles in an Inorganic Matrix Using TOF-SIMS Validated with STEM and EDX. | LitMetric

3D Imaging of Nanoparticles in an Inorganic Matrix Using TOF-SIMS Validated with STEM and EDX.

Anal Chem

Empa, Swiss Federal Laboratories for Materials Science and Technology , Laboratory for Mechanics of Materials and Nanostructures , Feuerwerkerstrasse 39 , CH-3602 Thun , Switzerland.

Published: September 2019

Imaging nano-objects in complex systems such as nanocomposites using time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a challenging task. Due to a very small amount of the material and a matrix effect, the number of generated secondary ions can be insufficient to represent a 3D elemental distribution despite being detected in a mass spectrum. Therefore, a model sample consisting of a ZrCuAg matrix with embedded Al nanoparticles is designed. A high mass difference between the light Al and heavy matrix components limits mass interference. The chemical structure measurements using a pulsed 60 keV Bi beam or a continuous 30 keV Ga beam reveals distinct Al signal segregation. This can indicate a spatially resolved detection of single 10s of nanometer large particles and/or their agglomerates for the first time. However, TOF-SIMS images of 50 nm or smaller objects do not necessarily represent their exact size and shape but can rather be their convolutions with the primary ion beam shape. Therefore, the size of nanoparticles (25-64 nm) was measured using scanning transmission electron microscopy. Our studies prove the capability of TOF-SIMS to image chemical structure of nanohybrids which is expected to help building new functional materials and optimize their properties.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.9b02545DOI Listing

Publication Analysis

Top Keywords

chemical structure
8
kev beam
8
imaging nanoparticles
4
nanoparticles inorganic
4
matrix
4
inorganic matrix
4
tof-sims
4
matrix tof-sims
4
tof-sims validated
4
validated stem
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!