Purpose: This study aims to compare the functional outcomes of nonunion humeral diaphyseal fractures following conservative treatment when managed surgically with either a plate or intramedullary (IM) nail fixation.

Methods: This was a retrospective study of 56 patients with nonunion humeral fractures following conservative treatment who underwent plate or IM nail fixation between 2007 and 2014. Comparison was made for short term profile (intraoperative blood loss, duration of surgery, and length of hospitalization) and long term clinical outcome with functional score (Constant-Murley score (CMS)) and Disabilities of the Arm, Shoulder and Hand (DASH) score). The union and complication rate were also compared.

Results: There were 36 and 20 patients included in plate and IM nail fixation group with the average of 36.14 ± 7.54-month follow-up time. The intraoperative blood loss, duration of surgery, and length of hospitalization were superior in IM nail group compared to plate group (p < 0.001, p < 0.001, and p < 0.001, respectively). The mean CMS and DASH score were superior in the plate group compared to the IM nail group (82.40 ± 16.84 versus 77.58 ± 12.96; 17.46 ± 11.05 versus 20.86 ± 11.63, respectively; with p = 0.246, p = 0.299, respectively). Plate fixation group showed higher union rate and complication rate compared to IM nail group (100% versus 90%, 13.8% versus 10%, respectively).

Conclusions: IM nail and plate fixation demonstrated comparable clinical outcome. IM nail fixation showed superior short term result with lower complication rate which benefits the elderly group patients with significant comorbidities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679862PMC
http://dx.doi.org/10.1155/2019/9107898DOI Listing

Publication Analysis

Top Keywords

nail fixation
12
complication rate
12
nail group
12
humeral diaphyseal
8
nonunion humeral
8
fractures conservative
8
conservative treatment
8
nail
8
plate nail
8
short term
8

Similar Publications

Robot-Assisted Retrograde Elastic Intramedullary Nailing Versus ORIF with a Plate for Displaced Midshaft Clavicular Fractures.

JB JS Open Access

January 2025

Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Capital Medical University, Beijing, People's Republic of China.

Background: The objective of this study was to compare the clinical outcomes of robot-assisted retrograde elastic intramedullary nailing and open reduction and internal fixation (ORIF) with a plate for displaced midshaft clavicular fractures.

Methods: All patients diagnosed with displaced midshaft clavicular fractures between November 1, 2022, and June 30, 2023, in our level-III hospital (most advanced level) were enrolled in this retrospective study; a total of 116 patients met the inclusion criteria. Patients were divided into 2 groups on the basis of treatment: robot-assisted retrograde elastic intramedullary nailing (RAN group) and ORIF with a plate (plate group).

View Article and Find Full Text PDF

Introduction: Intramedullary tibial nailing is a standard treatment for tibial shaft fractures. Postoperative knee pain significantly impacts functional recovery; however, studies on this issue are limited. This study evaluated the effect of the parapatellar approach for intramedullary nailing on postoperative knee pain.

View Article and Find Full Text PDF

This study introduces a novel anchor-type proximal femoral nail (AT-PFN) to improve the bone-fixation integrity over the standard screw-type nail (SST-PFN). Quasi-static incremental cyclic load test was performed to investigate load-displacement, cumulative deformation energy, time-strain, and backbone curves. The finite element analysis (FEA) was implemented to identify the stress and strain distributions.

View Article and Find Full Text PDF

Purpose: Tibial open shaft fractures are very common and susceptible to infection, which can lead to significant morbidity especially infection and non-union. Antibiotic coated nail is one option for fixing open shaft tibial fractures to minimise infection. This study aimed to compare the clinical outcome of Gentamicin-coated tibial nails versus regular unreamed interlocking tibial nails in the treatment of type I and II tibial open fractures.

View Article and Find Full Text PDF

Carbon fibre reinforced polyetheretherketone (CFR-PEEK) implants have gained interest because of reported biomechanical advantages and radio-lucent properties. The aim of this study was to evaluate the role of CFR-PEEK nails in patients with metastatic bone disease (MBD). We performed a retrospective cohort study evaluating patients with MBD undergoing intramedullary (IM) nailing for prophylaxis or fixation of pathological fractures using CFR- PEEK or titanium implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!