Background: Following total hip replacement (THR), hip geometry reconstruction parameters such as the femoral offset (FO) correlate with hip stability and wear. The purpose of this study is to determine the relationship between hip geometry parameters and knee and hip joint loading during walking.

Methods: Forty-one patients were examined before and a minimum of 1 year after primary THR. Pearson correlation coefficient (r) was performed to identify relationships between radiographic parameters and gait data. In addition, we divided patients into 2 groups according to the restoration of the FO (within ±5 mm vs more than 5 mm increment).

Results: The FO and global offset (GO) showed a positive correlation with the first (r = 0.469, P = .002; r = 0.542, P < .001) and second (r = 0.365, P = .019; r = 0.484, P = .001) knee adduction moment (KAM). The neck-shaft angle revealed a negative correlation with the first hip adduction moment (r = -0.375, P = .047). The reconstruction of FO with an increment of more than 5 mm was associated with a significant higher first KAM (+16%, P = .045) compared to the restored group.

Conclusion: Our findings suggest that abnormal hip and knee joint loading during walking after THR have a biomechanical background originating from hip geometry reconstruction. Patients with a high FO/GO were more likely to have an increased KAM during walking or vice versa. Surgeons need to be aware that an accurate control of FO, GO, and neck-shaft angle restoration in THR has an impact on hip and knee joint loading that may influence degenerative changes of the knee and higher wear of the artificial hip joint, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2019.07.027DOI Listing

Publication Analysis

Top Keywords

hip geometry
16
geometry reconstruction
12
hip
12
hip knee
12
knee joint
12
joint loading
12
total hip
8
hip replacement
8
hip joint
8
adduction moment
8

Similar Publications

Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study.

Cureus

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.

Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.

View Article and Find Full Text PDF

Background: Improvements in cementless total hip arthroplasty have been directed at optimizing osseointegration of the femoral implant to reduce aseptic loosening rates. Stem design plays a critical role in the performance of these implants. Given the increase in new stem designs and the creation of an updated classification system, improved understanding of the outcomes of each stem type is warranted.

View Article and Find Full Text PDF

Acetabular orientation, pelvic shape, and the evolution of hominin bipedality.

J Hum Evol

January 2025

Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO 65212, USA.

Hominin pelvic form differs dramatically from that of other primates by having more laterally facing iliac blades, a wider sacrum, and a larger, transversely broad pelvic inlet. The orientation of the acetabulum may also differ, plausibly related to differences in load transmission during upright posture and habitual bipedal locomotion, which may, in turn, affect overall pelvic geometry. We compared acetabular orientation in humans, a phylogenetically broad sample of extant anthropoid primates, and fossil hominins including Australopithecus afarensis (A.

View Article and Find Full Text PDF

Patient-specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient-specific implant designed to address a superior-medial defect created in a standard pelvic geometry.

View Article and Find Full Text PDF

Effect of a high-impact exercise program on hip strength indices in a group of obese women after bariatric surgery.

J Clin Densitom

December 2024

Department of Physical Education, Faculty of Arts and Sciences, University of Balamand, PO Box 100, Tripoli, Lebanon. Electronic address:

The purpose of this study was to explore the influence of a 12-month high-impact physical training program (descending stairs) on bone health in a group of young obese women who had undergone bariatric surgery (type sleeve). Fifty-two premenopausal women with a body mass index (BMI) > 35 kg/m (range: 35.06-60.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!