Intra- and Inter-Observer Reliability of Qualitative Behaviour Assessments of Housed Sheep in Norway.

Animals (Basel)

Department of Production Animal Clinical Sciences, Faculty of Veterinary Medicine, Norwegian University of Life Sciences, P.O. Box 369 Sentrum, 0102 Oslo, Norway.

Published: August 2019

This study tested the reliability of a Qualitative Behavioural Assessment (QBA) protocol developed for the Norwegian Sheep House () project. The aim was to verify whether QBA scores were consistent between different observers, i.e., inter-observer reliability, and between scorings of the same observers on different time points, i.e., intra-observer reliability. Six trained observers, including two veterinary students, two animal welfare inspectors and two sheep farmers observed sheep in 16 videos, and independently scored 14 pre-defined behavioural descriptors on visual analogue scales (VAS). The procedure was repeated one week after the first scoring session. QBA scores were analysed using Principal Component Analysis. Inter- and intra-observer agreement was assessed using Kendall's coefficient of concordance (). Principal component 1 (PC 1) and 2 (PC 2) combined explained >60% of the total variation in the QBA scores in both scoring sessions. PC 1 (44.5% in sessions 1 and 2) ranged from the positive descriptors calm, content, relaxed and friendly to the negative descriptors uneasy, vigilant and fearful, and was therefore labelled mood. PC 2 (18% in session 1, 16.6% in session 2) ranged from bright to dejected and apathetic, and was therefore labelled arousal. Kendall's coefficient of concordance of PC 1 for all observers was high in the two scoring sessions ( = 0.87 and 0.85, respectively), indicating good inter-observer reliability. For PC 2, the agreement for all observers was moderate in both video sessions ( = 0.45 and 0.65). The intra-observer agreement was very high for all observers for PC 1 ( > 0.9) except for one, where the agreement was considered to be high ( = 0.89). For PC 2, Kendall's coefficient was very high for the veterinary students and interpreted as moderate for the two farmers and welfare inspectors. This study indicates that the QBA approach and the terms included in the protocol were reliable for assessing video recordings of sheep behaviour when applied by trained observers, regardless of whether they were a veterinary student, animal welfare inspector or sheep farmer. Further work is needed to examine the reliability of the QBA protocol when tested on-farms for sheep managed under Norwegian housing systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6719082PMC
http://dx.doi.org/10.3390/ani9080569DOI Listing

Publication Analysis

Top Keywords

inter-observer reliability
12
qba scores
12
kendall's coefficient
12
reliability qualitative
8
qba protocol
8
trained observers
8
veterinary students
8
animal welfare
8
welfare inspectors
8
principal component
8

Similar Publications

Purpose: No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes.

Methods: X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected.

View Article and Find Full Text PDF

Purpose: To propose a new sign of patellar maltracking in recurrent patellar dislocation (RPD) and compare the differences in lower limb rotational and bony structural abnormalities among the different signs.

Patients And Methods: A retrospective study included 279 patients (mean age: 22 years; female: 81%) who underwent primary surgery for RPD over the past 4 years was performed. The patients were grouped based on the characteristics of patellar tracking: low-, moderate- and high-grade J-sign.

View Article and Find Full Text PDF

Objectives: Multiple techniques have been proposed for functional fetal cardiology, including pulsed-wave (PW) and tissue Doppler imaging (TDI), Myocardial Performance Index (MPI), annular plane systolic excursion (TAPSE/MAPSE) and spatiotemporal image correlation (STIC). We aimed to compare these techniques' achievability and reproducibility to determine their clinical utility for each cardiac side.

Methods: Uncomplicated pregnancies from 22 to 39 weeks were recruited and images and volumes stored for offline analysis.

View Article and Find Full Text PDF

Node Reporting and Data System 1.0 (Node-RADS) for the Assessment of Oncological Patients' Lymph Nodes in Clinical Imaging.

J Clin Med

January 2025

Radiology, Multizonal Unit of Rovereto and Arco, APSS Provincia Autonoma Di Trento, 38123 Trento, Italy.

The assessment of lymph node (LN) involvement with clinical imaging is a key factor in cancer staging. Node Reporting and Data System 1.0 (Node-RADS) was introduced in 2021 as a new system specifically tailored for classifying and reporting LNs on computed tomography (CT) and magnetic resonance imaging scans.

View Article and Find Full Text PDF

Purpose: This study aimed to clarify the applicability of smartphone-based three-dimensional (3D) surface imaging for clinical use in oral and maxillofacial surgery, comparing two smartphone-based approaches to the gold standard.

Methods: Facial surface models (SMs) were generated for 30 volunteers (15 men, 15 women) using the Vectra M5 (Canfield Scientific, USA), the TrueDepth camera of the iPhone 14 Pro (Apple Inc., USA), and the iPhone 14 Pro with photogrammetry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!