  • Medical laboratory testing often requires venous blood samples, which can be painful and difficult to collect due to the challenges of locating suitable veins.
  • The paper reviews various low-cost vein finder prototypes that utilize near-infrared (NIR) light technology to improve the accuracy of venous access and reduce discomfort for patients.
  • Despite some advancements, the development of these prototypes still faces challenges, such as limited human testing, variations in methodologies, and the need for more comprehensive assessments of phlebotomist performance when using these devices.

Article Abstract

One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. : Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. : Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. : The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6719195PMC
http://dx.doi.org/10.3390/s19163573DOI Listing

Publication Analysis

Top Keywords

vein finder
24
vein
12
infrared nir
12
low-cost vein
8
finder prototypes
8
prototypes utilizing
8
nir light
8
vein selection
8
publications assessment
8
finder
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!