Case: Intramedullary humeral lengthening is still a very uncommon procedure to treat humeral limb length discrepancy (LLD). This approach has various advantages compared with external devices but is limited in its ability to lengthen bones because of the length of the telescopic nail. This case report describes a middle-aged patient with a short right humerus secondary to a childhood growth plate injury that was successfully lengthened with an off-label application of a tibial distracting device. Hereby, a novel treatment technique with unlocking, backwinding, and reinterlocking of the telescopic nail for extended humeral distraction was performed.
Conclusions: Extended intramedullary humeral lengthening with unlocking, backwinding, and reinterlocking of the nail is a cost-effective, minimally invasive procedure in cases of massive humeral LLD with limitations in the distraction capacity of the telescopic nail.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.CC.18.00174 | DOI Listing |
J Orthop Surg Res
January 2025
Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.
Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.
Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.
Rev Bras Ortop (Sao Paulo)
November 2024
Departamento de Cirurgia Ortopédica, Fundación Clinica Shaio, Bogotá, Colômbia.
Floating elbow is a complex and rare entity caused by high-energy trauma. In this paper, we present the case of a patient who suffered a traffic accident with severe head trauma, floating elbow (humeral diaphyseal fracture, radial proximal diaphyseal fracture, and ulnar segmental fracture) and radial nerve injury. Fixations were made with a humeral plate and intramedullary rods in the forearm.
View Article and Find Full Text PDFInjury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFArch Bone Jt Surg
January 2024
Department of Shoulder and Elbow Surgery, Center for Orthopedic Surgery, the Third Affiliated Hospital of Southern Medical University, China.
Malays Orthop J
November 2024
Department of Orthopaedic Surgery, Japanese Red Cross Ashikaga Hospital, Tochigi, Japan.
Introduction: Antegrade intramedullary nail fixation for humeral shaft fractures yields satisfactory union rates. However, one of the related concerns is damage to the rotator cuff during nail insertion, which may affect long-term outcomes. The effect of a rotator cuff lesion on mid- and long-term shoulder outcomes remains unknown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!