We propose a new lateral force feedback device, the UltraShiver, which employs a combination of in-plane ultrasonic oscillation (around 30 kHz) and out-of-plane electroadhesion. It can achieve a strong active lateral force (400 mN) on the bare fingertip while operating silently. The lateral force is a function of pressing force, lateral vibration velocity, and electroadhesive voltage, as well as the relative phase between the velocity and voltage. In this paper, we perform experiments to investigate characteristics of the UltraShiver and their influence on lateral force. A lumped-parameter model is developed to understand the physical underpinnings of these influences. The model with frequency-weighted electroadhesion forces shows good agreement with experimental results. In addition, a Gaussian-like potential well is rendered as an application of the UltraShiver.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TOH.2019.2934853DOI Listing

Publication Analysis

Top Keywords

lateral force
20
force feedback
8
bare fingertip
8
ultrasonic oscillation
8
force
6
lateral
5
ultrashiver
4
ultrashiver lateral
4
feedback bare
4
fingertip ultrasonic
4

Similar Publications

Vestibular dysfunction has been reported as a potential cause in adolescent idiopathic scoliosis (AIS). However, it remained unclear how stochastic galvanic vestibular stimulation (GVS) affected kinetic performance of patients with AIS. This study aimed to investigate the effect of stochastic GVS on ground reaction forces (GRF) measures during obstacle negotiation among patients with AIS.

View Article and Find Full Text PDF

With the advancement of ecological and environmental protection construction, the research on the modification of expansive soil using environmentally friendly polymers can make up for the harm to the ecological environment caused by traditional modification. Mechanical and microscopic properties of modified expansive soils were analyzed through indoor tests. The results showed that the liquid limit and plasticity index decreased by 52.

View Article and Find Full Text PDF

Background: Limitations to using the knee as donor cartilage include cartilage thickness mismatch and donor site morbidity. Using the radial head as donor autograft for capitellar lesions may allow for local graft harvest without distant donor site morbidity. The purpose of this study is to demonstrate the feasibility of performing local osteochondral autograft transfer from the nonarticular cartilaginous rim of the radial head to the capitellum.

View Article and Find Full Text PDF

The forearm muscles coordinately control wrist motion, and their activity is affected by forearm rotation. Although forearm rotation has been implicated in the development of lateral and medial epicondylitis, its biomechanical background remains unknown. Therefore, the present study investigated the activity of wrist muscles in various forearm positions.

View Article and Find Full Text PDF

Background: Total knee arthroplasty (TKA) is one of the most common orthopaedic procedures and the number of patients which undergo TKA will continue to rise in the coming years. Consecutively, the number of necessary revision surgeries will increase. One of the main reasons for revision surgery is aseptic loosening because of a so-called stress-shielding effect.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!