Accurate pulmonary nodule detection is a crucial step in lung cancer screening. Computer-aided detection (CAD) systems are not routinely used by radiologists for pulmonary nodule detection in clinical practice despite their potential benefits. Maximum intensity projection (MIP) images improve the detection of pulmonary nodules in radiological evaluation with computed tomography (CT) scans. Inspired by the clinical methodology of radiologists, we aim to explore the feasibility of applying MIP images to improve the effectiveness of automatic lung nodule detection using convolutional neural networks (CNNs). We propose a CNN-based approach that takes MIP images of different slab thicknesses (5 mm, 10 mm, 15 mm) and 1 mm axial section slices as input. Such an approach augments the two-dimensional (2-D) CT slice images with more representative spatial information that helps discriminate nodules from vessels through their morphologies. Our proposed method achieves sensitivity of 92.7% with 1 false positive per scan and sensitivity of 94.2% with 2 false positives per scan for lung nodule detection on 888 scans in the LIDC-IDRI dataset. The use of thick MIP images helps the detection of small pulmonary nodules (3 mm-10 mm) and results in fewer false positives. Experimental results show that utilizing MIP images can increase the sensitivity and lower the number of false positives, which demonstrates the effectiveness and significance of the proposed MIP-based CNNs framework for automatic pulmonary nodule detection in CT scans. The proposed method also shows the potential that CNNs could gain benefits for nodule detection by combining the clinical procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TMI.2019.2935553 | DOI Listing |
J Orthop Surg Res
January 2025
Xuzhou Medical University Affiliated Stomatology Hospital, Xuzhou, 221002, Jiangsu Province, China.
Purpose: We aimed to explore the mechanism by which Boron-doped nano-hydroxyapatite (B-nHAp) facilitates the proliferation and differentiation of osteoblasts through controlled release of B.
Methods: B-nHAp characterization was accomplished by means of X-ray diffraction, scanning electron microscopy, inductively coupled plasma mass spectrometry, and transmission electron microscopy. Human bone marrow mesenchymal stem cells (hBMSCs) were subjected to flow cytometry, alizarin red S staining, and cell counting kit-8 assay for proliferation and differentiation determination.
Abdom Radiol (NY)
January 2025
University of Calgary, Calgary, Canada.
Objectives: Contrast enhanced ultrasound (CEUS) now joins the ranks of CT and MRI for noninvasive diagnosis of hepatocellular carcinoma (HCC). CEUS LI-RADS provides greater than 95% specificity for diagnosis within LR-5. Unlike CT/MRI, CEUS is nodule based.
View Article and Find Full Text PDFEur J Radiol
January 2025
Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:
Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.
Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.
Ann Surg Oncol
January 2025
Division of Pancreatic Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Introduction: Laparoscopic distal pancreatectomy (LDP) has the advantages of reduced blood loss, shorter hospital stays, and a better postoperative quality of life compared with open distal pancreatectomy (ODP). Meanwhile, spleen-preserving laparoscopic distal pancreatectomy is the preferred technique for low-grade malignant and benign tumors located in pancreatic body and tail, since it preserves the immune function of the spleen. The splenic-vessel-preserving (SVP) Kimura technique and splenic vessel resection Warshaw technique are the two primary procedures.
View Article and Find Full Text PDFAcad Emerg Med
January 2025
Department of Emergency Medicine, Yale University, New Haven, Connecticut, USA.
Objectives: For emergency department (ED) patients, lung cancer may be detected early through incidental lung nodules (ILNs) discovered on chest CTs. However, there are significant errors in the communication and follow-up of incidental findings on ED imaging, particularly due to unstructured radiology reports. Natural language processing (NLP) can aid in identifying ILNs requiring follow-up, potentially reducing errors from missed follow-up.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!