Objective: Since the first introduction of the MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) score, significant progress has been made with regard to surgical treatment options for cartilage defects, as well as magnetic resonance imaging (MRI) of such defects. Thus, the aim of this study was to introduce the MOCART 2.0 knee score - an incremental update on the original MOCART score - that incorporates this progression.

Materials And Methods: The volume of cartilage defect filling is now assessed in 25% increments, with hypertrophic filling of up to 150% receiving the same scoring as complete repair. Integration now assesses only the integration to neighboring native cartilage, and the severity of surface irregularities is assessed in reference to cartilage repair length rather than depth. The signal intensity of the repair tissue differentiates normal signal, minor abnormal, or severely abnormal signal alterations. The assessment of the variables "subchondral lamina," "adhesions," and "synovitis" was removed and the points were reallocated to the new variable "bony defect or bony overgrowth." The variable "subchondral bone" was renamed to "subchondral changes" and assesses minor and severe edema-like marrow signal, as well as subchondral cysts or osteonecrosis-like signal. Overall, a MOCART 2.0 knee score ranging from 0 to 100 points may be reached. Four independent readers (two expert readers and two radiology residents with limited experience) assessed the 3 T MRI examinations of 24 patients, who had undergone cartilage repair of a femoral cartilage defect using the new MOCART 2.0 knee score. One of the expert readers and both inexperienced readers performed two readings, separated by a four-week interval. For the inexperienced readers, the first reading was based on the evaluation sheet only. For the second reading, a newly introduced atlas was used as an additional reference. Intrarater and interrater reliability was assessed using intraclass correlation coefficients (ICCs) and weighted kappa statistics. ICCs were interpreted according to Koo and Li; weighted kappa statistics were interpreted according to the criteria of Landis and Koch.

Results: The overall intrarater (ICC = 0.88, < 0.001) as well as the interrater (ICC = 0.84, < 0.001) reliability of the expert readers was almost perfect. Based on the evaluation sheet of the MOCART 2.0 knee score, the overall interrater reliability of the inexperienced readers was poor (ICC = 0.34, < 0.019) and improved to moderate (ICC = 0.59, = 0.001) with the use of the atlas.

Conclusions: The MOCART 2.0 knee score was updated to account for changes in the past decade and demonstrates almost perfect interrater and intrarater reliability in expert readers. In inexperienced readers, use of the atlas may improve interrater reliability and, thus, increase the comparability of results across studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8725373PMC
http://dx.doi.org/10.1177/1947603519865308DOI Listing

Publication Analysis

Top Keywords

knee score
24
mocart knee
20
cartilage repair
16
expert readers
16
inexperienced readers
16
magnetic resonance
12
repair tissue
12
interrater reliability
12
readers
9
mocart
8

Similar Publications

Aim: This study evaluates the prevalence, risk factors, and quality of life of patients with knee osteoarthritis (OA) in the Indonesian population.

Method: A cross-sectional study of 3597 adults (≥ 18 years old) was conducted in 2023 involving 15 different cities in Indonesia. Knee OA was classified according to the clinical ACR criteria.

View Article and Find Full Text PDF

Background This study hypothesizes that patients with femoral condylar hypoplasia who undergo total knee arthroplasty (TKA) may experience femoral component malrotation and that the surgeon performing the operation may not notice it. The aim is to measure the rotational alignment of the femoral components and assess the functional outcomes in these patients. Materials and methods Between December 2018 and December 2022, a total of 96 knees from 80 patients were evaluated.

View Article and Find Full Text PDF

Background: Osteoarthritis (OA) often leads to pain and functional limitations, impacting work and daily life. Physical activity (PA) is an important part of the treatment. Wearable activity trackers (WATs) offer a novel approach to promote PA but could also aid in finding a sustainable PA level over time.

View Article and Find Full Text PDF

Background: Unicompartmental knee arthroplasty (UKA) is a surgical treatment for knee osteoarthritis associated with lower morbidity compared with total knee arthroplasty (TKA) in patients with isolated unicompartmental knee arthritis. As disparities have been noted broadly in arthroplasty care, it follows that such disparities might be present in the utilization of UKA relative to TKA. This study therefore examined racial/ethnic, socioeconomic, and payer status differences in utilization of UKA.

View Article and Find Full Text PDF

Patients with knee osteoarthritis (KOA) often have impaired muscle function of the weight-bearing muscles, particularly in the knee and hip joints. This can lead to a significant loss of strength and power and may play a role in the perceived instability of the knee joint. The purpose of this study was to compare the maximum isometric strength of the hip abductor and knee extensor muscles between patients with KOA with and without perceived instability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!