Endomyocarditis in Eosinophilic granulomatosis with polyangiitis (EGPA) is a rare complication, commonly involving an apical mass compatible with a thrombus. However, no previous report has discussed mobile structures detected by echocardiography in a patient with EGPA. A 53-year-old man with asthma presented with low-grade fever, consciousness disturbance, and vomiting. Magnetic resonance imaging showed multiple acute infarctions in the bilateral cerebrum and cerebellum. Remarkable eosinophilia was observed, and transthoracic echocardiography showed multiple mobile structures originating from the left ventricular septum. The day after admission, he developed left partial hemianopia and intracranial hemorrhage was identified in his right occipital lobe. Skin biopsy showed infiltration of eosinophils in the arterial wall, and we diagnosed EGPA. Myocardial biopsy was performed from the right ventricular wall, and eosinophilic infiltration into the endocardium and myocardium was observed. Endomyocarditis secondary to EGPA was confirmed, and steroid therapy was immediately initiated. Ten days after steroid therapy, the mobile structures in the left ventricle disappeared completely. He suffered no recurrence of stroke with continued steroid therapy. Mobile structures in the left ventricle in patients with active EGPA could be treated conservatively with steroid therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2019.104326 | DOI Listing |
Anal Chim Acta
February 2025
School of Laboratory Medicine, Hubei University of Chinese Medicine, 16 Huangjia Lake West Road, Wuhan, 430065, PR China; Hubei Shizhen Laboratory, Wuhan, Hubei, 430065, PR China. Electronic address:
Development of sensitive and cost-effective strategies for detecting influenza viruses is crucial to combat the spread of infectious diseases. In this study, a novel trans-dimensional nanocoral gold foam (NCGF) was fabricated on screen-printed carbon electrodes using hydrogen template electrodeposition method. This unique structure, with interconnected large and small pores, significantly increased the specific surface area and stability of the sensor.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, 0179, Tbilisi, Georgia. Electronic address:
Background: Isotopologues resulting from the labelling of molecules with deuterium have attracted interest due to the isotope effect observed in chemistry and biosciences. Isotope effect may also play out in noncovalent interactions and mechanisms leading to intermolecular recognition. In chromatography, differences in retention time between isotopologues, as well as between isotopomers have been observed resulting in two different elution sequences (isotope effects): the normal isotope effect when heavier isotopologues retain longer than lighter analogues, and the inverse isotope effect featuring the opposite elution order.
View Article and Find Full Text PDFBackground: Interactive electronic devices (IEDs) are ubiquitous in young children's lives. However, research on their impact on learning and development is still limited. The aim of this study was to understand the perspectives of early years practitioners (EYPs) and public health consultants (PHCs) on the use of IEDs in children aged 3-5.
View Article and Find Full Text PDFJ Chromatogr A
December 2024
Synthetic Molecule Pharmaceutical Science, gRED, Genentech, Inc., 1 DNA Way, South San Francisco, CA, 94080, United States. Electronic address:
Quantitative structure retention relation (QSRR) is an active field of research, primarily focused on predicting chromatography retention time (Rt) based on molecular structures of an input analyte on a single or limited number of reversed-phase HPLC (RP-HPLC) columns. However, in the pharmaceutical chemistry manufacturing and controls (CMC) settings, single-column QSRR models are often insufficient. It is important to translate retention time across different HPLC methods, specifically different stationary phases (SP) and mobile phases (MP), to guide the HPLC method development, and to bridge organic impurity profiles across different development phases and laboratories.
View Article and Find Full Text PDFInt J Food Microbiol
January 2025
College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi 712100, China. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!