We evaluated the diagnostic value of atrial fibrillation (AF) measured by a wrist-type pulse wave monitor in this case-control study. Six serial pulse wave values (three in the left and three in the right wrist) were measured using a wrist-type monitor in 29 AF patients and 30 subjects with sinus rhythm. We defined "monitor AF in irregular pulse peak (IPP) 15/20/25" as follows: (a) IPP: |interval of pulse peak - the average of the interval of the pulse peak| ≥ the average of the interval of the pulse peak × 15/20/25%; (b) irregular heartbeat (IHB): beats of IPP ≥ total pulse × 20%; and (c) monitor AF: ≥4 IHBs of the six pulse wave measurements. In IPP 15, the sensitivity and specificity were 0.97 and 1.00, respectively. Pulse wave analysis by a wrist-type monitor was shown to have high sensitivity and specificity for the diagnosis of AF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8030341PMC
http://dx.doi.org/10.1111/jch.13648DOI Listing

Publication Analysis

Top Keywords

pulse wave
20
pulse
9
atrial fibrillation
8
wrist-type pulse
8
wave monitor
8
measured wrist-type
8
wrist-type monitor
8
average interval
8
interval pulse
8
sensitivity specificity
8

Similar Publications

Background: Use of health applications (apps) to support healthy lifestyles has intensified. Different app features may support effectiveness, including gamification defined as the use of game elements in a non-game situation. Whether health apps with gamification can impact behaviour change and cardiometabolic risk factors remains unknown.

View Article and Find Full Text PDF

Aim: This study aims to investigate the effects of combining a multifunctional pulse wave sphygmomanometer with constant temperature ice on patients with forearm hematoma following coronary intervention.

Methods: Patients who developed forearm hematoma after undergoing coronary intervention from March 2021 to March 2023 at our hospital were selected as the study cohort. Using a random number table, they were divided into two groups the control group and the research group.

View Article and Find Full Text PDF

Deep Learning Analysis of White Matter Hyperintensity and its Association with Comprehensive Vascular Factors in Two Large General Populations.

J Imaging Inform Med

January 2025

Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-Ro 43-Gil, Seoul, 05505, Republic of Korea.

Although the relationships between basic clinical parameters and white matter hyperintensity (WMH) have been studied, the associations between vascular factors and WMH volume in general populations remain unclear. We investigated the associations between clinical parameters including comprehensive vascular factors and WMH in two large general populations. This retrospective, cross-sectional study involved two populations: individuals who underwent general health examinations at the Asan Medical Center (AMC) and participants from a regional cohort, the Korean Genome and Epidemiology Study (KoGES).

View Article and Find Full Text PDF

Runx2-NLRP3 Axis Orchestrates Matrix Stiffness-evoked Vascular Smooth Muscle Cell Inflammation.

Am J Physiol Cell Physiol

January 2025

Department of Physiology and Pathophysiology, School of Basic Medical Sciences, State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing 100191, China.

Arterial stiffening is a hallmark of chronic kidney disease (CKD) related cardiovascular events and is primarily attributed to the elevated matrix stiffness. Stiffened arteries are accompanied by low-grade inflammation, but the causal effects of matrix stiffness on inflammation remain unknown. For analysis of the relationship between arterial stiffness and vascular inflammation, pulse wave velocity (PWV) and aortic inflammatory markers were analyzed in an adenine-induced mouse model of CKD in chronological order.

View Article and Find Full Text PDF

Background: Venous waveform analysis is an emerging technique to estimate intravascular fluid status by fast Fourier transform deconvolution. Fluid status has been shown proportional to , the amplitude of the fundamental frequency of the waveform's cardiac wave upon deconvolution. Using a porcine model of distributive shock and fluid resuscitation, we sought to determine the influence of norepinephrine on of the central venous waveform.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!