Synthesized digital mammography (SM) was developed to replace digital mammography (DM) in digital breast tomosynthesis (DBT) imaging to reduce radiation dose. This survey assessed utilization and attitudes regarding SM in DBT screening. The study was institutional review board exempt. An online survey was sent to members of the Society of Breast Imaging in June 2018. Questions included practice information, utilization of DBT and SM, perception of change in recall rates (RRs) and cancer detection rates (CDRs) with SM-DBT versus DM-DBT, and attitudes regarding SM versus DM in DBT screening. χ Tests were used to compare response frequencies across groups. In all, 312 of 2,600 Society of Breast Imaging members responded to the survey (12%). Of respondents, 96% reported DBT capability, and 83% reported SM capability. Of those without SM, the most cited reasons were cost or administration and image quality concerns (both 32%). In addition, 40% reported combined SM and DM use in DBT screens, and 52% reported SM use without DM in the majority of DBT screens. The overall satisfaction with SM was 3.4 of 5 (1-5 scale). Most cited SM advantages were decreased dose (85%) and increased lesion conspicuity (27%). The most cited SM disadvantages were calcification characterization (61%) and decreased image quality (31%). Most respondents were unsure if CDRs changed (44%) and RR changed (30%) with few reporting adverse outcomes (6% RR increase, 1% CDR decrease). Most radiologists screening with DBT have SM, but only one-half have replaced DM with SM. Despite few reported adverse screening outcomes with SM-DBT, radiologists have concerns about image quality, specifically calcification characterization.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6952532 | PMC |
http://dx.doi.org/10.1016/j.jacr.2019.07.020 | DOI Listing |
BMC Womens Health
January 2025
Department of General Surgery, İstanbul Faculty of Medicine, İstanbul University, İstanbul, 34093, Türkiye.
Background: The Bahçeşehir population-based mammography screening program (BMSP) is an example of Türkiye's first population-based screening program. This study aims to reveal the successful implementation of population-based secreening program in one of the low- and middle-income countries, Türkiye and long-term results of patients diagnosed with breast cancer during BMSP.
Methods: This study was conducted between 2009 and 2019, in the Bahçeşehir county of Istanbul.
Gynecol Oncol
January 2025
New York University Langone Health, Long Island, Department of Obstetrics and Gynecology, Division of Gynecologic Oncology, Mineola, NY, United States of America. Electronic address:
Objectives: Women with germline BRCA1/2 pathogenic variants (gBRCA1/2) are recommended to undergo annual breast MRI and mammography. Our objective was to describe the frequency of insurance denials for annual breast MRIs in women with gBRCA1/2 and determine denial trends.
Methods: Women with gBRCA1/2 following in a high-risk breast cancer clinic with breast MRIs ordered from 2020 to 2021 were identified and cross-referenced with a database of insurance denials.
J Med Case Rep
January 2025
Department of Pathology and Laboratories, University Hospital Fundación Santa Fe de Bogotá, Bogotá, DC, Colombia.
Background: Adenoid cystic carcinoma of the breast is a rare subtype, constituting less than 3.5% of primary breast carcinomas. Despite being categorized as a type of triple-negative breast cancer, it generally has a favorable prognosis.
View Article and Find Full Text PDFCurr Probl Diagn Radiol
January 2025
Department of Medical Imaging, University of Arizona, 1501 N Campbell Ave, Tucson AZ 85724, USA; Banner University Medical Center Tucson, 1625 N Campbell Ave, Tucson AZ 85719, USA.
Breast magnetic resonance imaging (MRI) has the highest sensitivity for breast cancer detection compared to other breast imaging modalities such as mammography and ultrasound. As a functional modality, it captures the increased angiogenic activity of breast cancer through gadolinium-based contrast enhancement. Normal breast tissue also enhances, albeit in distinct patterns termed background parenchymal enhancement (BPE).
View Article and Find Full Text PDFMed Phys
January 2025
Breast Imaging Department, Red Cross Hospital Munich, Munich, Germany.
Background: A significant proportion of false positive recalls of mammography-screened women is due to benign breast cysts and simple fibroadenomas. These lesions appear mammographically as smooth-shaped dense masses and require the recalling of women for a breast ultrasound to obtain complementary imaging information. They can be identified safely by ultrasound with no need for further assessment or treatment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!