Background: The instructions of manufacturers of methodologies for anti-HIV-1/2 antibodies screening tests re-commend avoiding analyzing blood samples with hemolysis or lipemia, but they do not mention references about scientific studies evaluating their interference. The increased need for an opportune detection of HIV infection to avoid its spread has led to public health institutions including routine HIV screening even in internal medicine and emergency rooms. Nevertheless, these blood samples are usually associated with the presence of lipemia and/ or hemolysis, leaving doubt for probable misinterpretations. This fact highlights the need for applying verification techniques, established under the internal methodological conditions of each laboratory, in order to increase the coverage of HIV screening and to ensure the reliability of their results.
Methods: Following the ethics committee approval and patient's informed consent, a confirmed anti-HIV-1 positive human serum (undetectable viral load and p24 antigen, and stable total lymphocytes > 30%) was obtained. This work describes techniques for the semiquantitative analysis of anti-HIV antibodies of three commercial HIV-screening methodologies (immunochromatography, enzyme-immunoassay and chemiluminescence) and to deter-mine the detection limit of these screening tests, as well as evaluating the maximum concentration of total lipids and of free hemoglobin that do not interfere in the detection limits.
Results: The highest analyzed concentration of total lipid (870 mg/dL) did not interfere with the detection limits of anti-HIV-1 antibodies in any of the evaluated methodologies. Free hemoglobin presented interference at different concentrations depending on the methodology: immunochromatography (0.57 g/dL)), enzyme-immunoassay (8.6 g/dL), and chemiluminescence (11.5 g/dL)).
Conclusions: Concentrations of lipemia above postprandial levels or hemolysis induced by experimental manipulation might not interfere with HIV-serological screening. Determining the maximum permissible limits of lipemia and hemolysis by each manufacturer or laboratory based on an internal evaluation of their serological methodology would increase the reliability of HIV-diagnosis in internal medicine and emergency rooms and in patients with dyslipidemia or physiological hemolysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7754/Clin.Lab.2019.181123 | DOI Listing |
Clin Chem Lab Med
December 2024
Department of Clinical Chemistry, 162073 Sestre Milosrdnice University Hospital Center, Zagreb, Croatia.
Objectives: Autoverification increases the efficiency of laboratories. Laboratories accredited according to ISO 15189:2022 need to validate their processes, including autoverification, and assess the associated risks to patient safety. The aim of this study was to propose a systematic verification algorithm for autoverification and to assess its potential risks.
View Article and Find Full Text PDFClin Chem Lab Med
November 2024
Utrecht University, Utrecht, The Netherlands.
Objectives: This study examined the comparability of venous and capillary blood samples with regard to routine chemistry analytes.
Methods: Venous and capillary blood samples were collected from adult patients to assess comparability of alanine transaminase, albumin, alkaline phosphatase, apolipoprotein B, aspartate aminotransferase, total bilirubin, calcium, chloride, creatin kinase, creatinine, C-reactive protein, ferritin, folic acid, free T4, gamma glutamyltransferase, glucose, high density lipoprotein cholesterol, iron, lipase, lipoprotein a, magnesium, phosphate, postassium, prostate specific antigen, sodium, total cholesterol, total protein, transferrin, triglycerides, thyroid stimulating hormone, urate, urea, vitamin B12 and 25-hydroxyvitamin-D3. Furthermore, hemolysis-icterus-lipemia Index (HIL-Index) was measured for all samples.
Transfusion
November 2024
Research and Development, Australian Red Cross Lifeblood, Alexandria, New South Wales, Australia.
Background: Whole blood (WB) is increasingly being used for resuscitation of trauma patients. Although platelet-, red blood cell (RBC)- and plasma-specific parameters in cold-stored WB are well characterized, there has been limited investigation of biological response modifiers (BRMs), which may induce adverse reactions in recipients. The aim of this study was to evaluate the quality and function of RBC, platelets, plasma proteins, and BRMs in cold-stored WB during storage.
View Article and Find Full Text PDFScand J Clin Lab Invest
November 2024
Department of Experimental Medicine, University of Rome Tor Vergata, Rome, Italy.
The erythrocyte sedimentation rate (ESR) is a widely used diagnostic test, influenced by all physiological and pathological conditions that can bias blood rheology by interfering factors. This study aimed to evaluate the performance of the CUBE 30 touch ESR analyzer in samples with preanalytical variables, as lipemia, hemolysis, and icterus or in presence of fibrinogen., Moreover we focused to define the maximum time limits to ensure a reliable ESR measure.
View Article and Find Full Text PDFVet Sci
October 2024
MacroArray Diagnostics, Lemböckgasse 59, 1230 Vienna, Austria.
Detecting IgE sensitizations in the serum of allergic dogs is commonly performed using allergen extracts, but these are difficult to standardize. This article details the development and validation of the Pet Allergy Xplorer (PAX; Nextmune, Stockholm, Sweden), the first multiplex macroarray for the detection of IgE sensitization in dogs using allergen extracts and molecular components; the PAX is derived from the Allergy Xplorer (ALEX; MacroArray Diagnostics, Vienna, Austria). The selection of allergens, cartridge processing, strategy for identifying and blocking IgE directed against cross-reactive carbohydrate determinants (CCDs), and the method used for determining the positivity threshold are described.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!