Objective: The reliability of heart rate variability (HRV) analysis is not yet fully understood, especially considering different body positions and the mathematical influence of heart rate. The aim of this study was to evaluate the reliability of HRV in supine and standing positions, with and without mathematical adjustment of HRV by the average R-R interval (iRR).

Methods: We evaluated 37 young males (23.1±4 years; 25.1±3 kg/m2). A 5-min segment of the iRR was collected in the supine and standing positions on three occasions separated by 48-hour intervals. Absolute and relative reliability of temporal and spectral indices were assessed by the coefficient of variation (CV) and the intraclass correlation coefficient (ICC), respectively.

Results: We did not observe differences in HRV indices in the three occasions in the supine or standing position (p>0.05). Moderate to good reproducibility was observed for temporal and spectral indices of HRV in the supine position (ICC: 0.65-0.89; CV: 0.9-19.8). In the orthostatic position, low to good reproducibility was observed (ICC: 0.35-0.89; CV: 1.1-34.8), with higher ICCs for temporal indices. After mathematical adjustment, only a small modification in HRV reliability was observed in both positions.

Conclusions: In young adult males, the mathematical adjustment of HRV by the average iRR led to a nonsignificant effect on HRV reliability. Additionally, HRV reliability is dependent on body position and the index analyzed. Promising measures in both supine and standing positions include r-MSSD and the HF band (parasympathetic indices).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6683304PMC
http://dx.doi.org/10.6061/clinics/2019/e806DOI Listing

Publication Analysis

Top Keywords

supine standing
20
heart rate
16
standing positions
16
mathematical adjustment
12
hrv reliability
12
hrv
9
rate variability
8
positions mathematical
8
hrv supine
8
adjustment hrv
8

Similar Publications

: The COVID-19 pandemic highlighted that body positions substantially affected the mortality rate. We hypothesized that body position modulates the contribution of abdominal (AB) and thoracic breathing (TB) to the breathing cycle (BC), as well as respiratory rate (RR). In addition, we hypothesized that physical activity level can increase the contribution of abdominal breathing.

View Article and Find Full Text PDF

Purpose: Worsening sagittal alignment of the spine, particularly kyphosis, may cause difficulty in assuming a supine position, restricting sleeping posture and movement and potentially leading to sleep disturbances. However, no studies have explored the relationship between sagittal spinal alignment and sleep disturbance. This study aimed to clarify the relationship between sagittal spinal alignment and sleep disturbance.

View Article and Find Full Text PDF

Purpose: Achieving precise postoperative alignment is critical for the long-term success of total knee arthroplasty (TKA). Long-leg standing radiograph (LLR) at 6 weeks post-op is the gold standard for assessing alignment, but its reliance on weight-bearing and positioning makes it less practical in the early postoperative period. Supine computed tomography scanogram (CTS) offers a potential alternative.

View Article and Find Full Text PDF

Analysing the support mechanisms of the vaginal ring pessary on supine and upright MRI.

Sci Rep

December 2024

Multi-Modality Medical Imaging (M3I), TechMed Centre, University of Twente, Technohal 2384,Drienerolaan 5, Enschede, 7522NB, The Netherlands.

Vaginal pessaries have been used for millennia to alleviate symptoms of pelvic organ prolapse (POP). Despite their long-standing use, the success rate of pessary treatment is approximately 60%, and the underlying mechanisms of support are not well understood. This study aims to investigate three previously proposed hypotheses regarding the support mechanisms of pessaries, utilizing supine and upright magnetic resonance imaging (MRI): (1) support by bony structures, (2) support by levator ani muscles (LAM), and (3) the uterus keeping the pessary in place by acting as a lever.

View Article and Find Full Text PDF

: Instability is a major reason for revision after total hip arthroplasty (THA), and acetabular cup placement in the "traditional" safe zone does not protect against dislocations. Spinopelvic mobility may play a role in impingement and dislocation after THA. Personalized acetabular cup placement that incorporates spinopelvic mobility is currently lacking in the literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!