Background: Endotracheal intubation is an important procedure in critical care and emergency medicine settings. Optimal depth of the tube placement has been a serious concern because of several complications associated with its malposition.
Objective: The aim of the current study was to find a new formula to estimate the proper endotracheal tube depth when using ultrasonography or lighted stylet device in order to increase the accuracy of determining Endotracheal tube (ETT) depth and decrease the side effects of ETT misplacement.
Method: Patients older than 18 years of age admitted to Imam emergency department who needed tracheal intubation were included. Tube's length at the angle of the mouth while the tube passed the suprasternal notch, ETT depth after insertion and the distance from ETT's tip to carina were recorded. Ultrasonography and portable chest x-ray were used as tools for measuring these lengths.
Results: A total number of 91 patients including 55 men and 36 women were eligible for inclusion in the study. Not placing the tube at proper depth was considered as the failure of intubation. This failure rate was 9.9% in the standard method which would have been 1.1% if our proposed formula was used.
Conclusion: The findings of this study suggest that the use of this new formula may help in predicting the proper intubation tube placement. Further studies are warranted to confirm these findings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6683597 | PMC |
http://dx.doi.org/10.22114/ajem.v0i0.154 | DOI Listing |
J Clin Med
December 2024
Department of Surgery IV, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 38 Gheorghe Marinescu Street, 540139 Targu Mures, Romania.
In recent decades, the advantages of minimizing surgical trauma have led to the development of minimally invasive surgical procedures. While the benefits often outweigh the risks, several challenges are encountered that are not present in conventional surgical approaches. Unilateral pulmonary edema (UPE) after mitral interventions performed through a right-sided approach is a rare but potentially life-threatening event.
View Article and Find Full Text PDFBiomedicines
December 2024
Department of Neonatology, Osaka Women's and Children's Hospital, Izumi 594-1101, Japan.
Background: It has been demonstrated that aspiration during endotracheal intubation in preterm infants with gastroesophageal reflux is a contributing factor in the worsening of lung diseases and the development of bronchopulmonary dysplasia (BPD). This study aims to compare the safety and efficacy of early transpyloric (TP) tube feeding with that of nasogastric (NG) tube feeding in relation to BPD.
Methods: The study population consisted of 39 extremely low birth weight infants (ELBWIs) with mechanical ventilation and an enteral feeding volume of 50 mL/kg/day, which were randomly assigned to different groups based on the method of tube feeding.
Cureus
December 2024
Radiology, SRM Medical College Hospital and Research Center, Chennai, IND.
Intraoperative neurophysiological monitoring (IONM) has achieved popularity because it facilitates monitoring of the functional integrity of neural structures under general anesthesia. It aids in the early detection of injury and minimizes postoperative neurologic deficit or neurologic morbidity from surgical manipulations of various neurologic structures. The patient mentioned in this case report presented with lower limb radiculopathy and was diagnosed with diastematomyelia Type II, and she was planned for surgical intervention under general anesthesia.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Propofol, a widely used intravenous anesthetic agent, requires accurate monitoring to ensure therapeutic efficacy and prevent oversedation. Recent developments in modern analytical instrumentation have led to significant breakthroughs in on-line analysis of exhaled breath. This review discusses several sophisticated analytical methods that have been explored for noninvasive, real-time monitoring of propofol concentrations, including proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, and gas chromatography coupled to surface acoustic wave sensors.
View Article and Find Full Text PDFJ Anaesthesiol Clin Pharmacol
August 2024
Department of Anesthesia and Critical Care, Pt. B. D. Sharma PGIMS, Rohtak, Haryana, India.
Background: Traditionally, the sniffing position has been considered a standard head and neck position during direct laryngoscopy. The perfect head and neck position for video laryngoscopy has yet not been described. Hence, we planned the present study to compare the neutral and sniffing position for ease of intubation using Airtraq.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!