Background: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM).
Methods: Anterior chamber depth (ACD), distance between corneal endothelium and anterior surface of ICL(C-ICL) and central vault were measured in 82 phakic myopic eyes of 82 patients who underwent ICL surgery, by using AS-OCT, Pentacam and UBM consecutively at 3 months follow up. The correlation and agreement of instruments were accessed by using Intraclass correlation coefficient (ICC) and the Bland-Altman plot.
Results: AS-OCT showed higher ACD, C -ICL and central vault measurements than both of Pentacam and UBM (P < 0.001), while Pentacam showed lower measurements than UBM (P < 0.05). The Pearson correlation coefficient (r) was 0.91 to 0.96, and ICC was 0.95 to 0.98 for all measurements between difference devices (all P < 0.001). The 95% limits of agreement of ACD, C-ICL, vault measurements were 0.13 to 0.38 mm, - 0.07 to 0.27 mm, 0.08 to 0.34 mm between AS-OCT and Pentacam, - 0.03 to 0.33 mm, - 0.16 to 0.31 mm, - 0.10 to 0.26 mm between AS-OCT and UBM, and - 0.29 to 0.07 mm, - 0.25 to 0.20 mm, - 0.31 to 0.05 mm between Pentacam and UBM, respectively.
Conclusions: AS-OCT demonstrated significantly higher value, while Pentacam demonstrated significantly lower value than UBM for ACD, C-ICL and central vault measurements in myopic eyes after ICL surgery. Measurements with these instruments were highly correlated, but could not replace each other especially for vault. This study provided valuable information about how to judge the results of anterior segment parameters of eyes implanted with ICL V4c from different devices.
Trial Registration: Registration number: ChiCTR-OOC-16008987 . Retrospectively registered: 08 August 2016.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693247 | PMC |
http://dx.doi.org/10.1186/s12886-019-1194-y | DOI Listing |
BMC Ophthalmol
January 2025
Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, 710004, China.
Background: This study aimed to identify the clinical characteristics of cases that is related to the response rate of adalimumab (ADA) treatment.
Methods: A retrospective review of medical records was conducted for pediatric patients with non-infectious uveitis undergoing ADA treatment for a minimum of six months. The patients were stratified into two groups: those with anterior segment inflammation (ASI+) and those without anterior segment inflammation (ASI-).
Klin Monbl Augenheilkd
January 2025
Ophthalmology, Amsterdam UMC, Amsterdam, Netherlands.
Background: Refractory corneal edema is the foremost reason for endothelial corneal transplantation (EK) in the world. Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) offer good clinical outcomes. However, human donor tissue is limited in availability and has a complex logistical chain.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
March 2025
Department of Ophthalmology and Visual Sciences, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki City, Nagasaki, 852-8501, Japan.
Purpose: Atovaquone is an alternative drug that is used for the prevention and treatment of pneumonia when the first-line drug, sulfamethoxazole-trimethoprim (ST combination), cannot be used due to side effects. However, atovaquone is known to cause ocular side effects including oculomucocutaneous syndrome and vortex keratopathy. In this report, we describe a patient who developed bilateral white granular diffuse corneal opacity that extended from the corneal sub-epithelium to the stroma after continuous oral atovaquone administration for 14 months.
View Article and Find Full Text PDFCureus
December 2024
Orthodontics and Dentofacial Orthopedics, Manav Rachna Dental College, Manav Rachna International Institute of Research and Studies, Faridabad, IND.
Vertical maxillary excess (VME) is a facial condition characterized by an increased height in the lower third of the face, leading to a longer overall facial appearance. This condition is linked to a significant proportion of malocclusions and is often associated with greater dissatisfaction among patients concerning their appearance. The amalgamation of orthodontics with surgery is a desirable protocol to address VME.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopaedics, Gandhi Medical College, Bhopal, Bhopal, IND.
Introduction Thoracolumbar fractures, particularly burst fractures, represent a significant health concern due to their prevalence and functional impact. This study evaluates the efficacy of short-segment posterior fixation with intermediate screw instrumentation in treating unstable thoracolumbar fractures. Methods A prospective study was conducted from July 2022 to December 2023, including 26 patients with traumatic thoracolumbar fractures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!