A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preparation of carboxylic graphene oxide-composited polypyrrole conduits and their effect on sciatic nerve repair under electrical stimulation. | LitMetric

Carboxylic graphene oxide-composited polypyrrole/poly-l-lactic acid (C-GO/PPy/PLLA) films were fabricated by electrochemical deposition of C-GO-composited PPy on PLLA fibers-film, and their conductivity and tensile strength (∼4.6 S/cm and 26.4 MPa, respectively) were stably remained after the immersion of 4 weeks, due to the hydrogen bond interaction between graphene oxide's carboxylic groups and pyrrole's imino groups. Their specific surface areas of ∼57.5 m /g and pore volume of ∼0.02 cm /g were significantly larger than those of PPy/PLLA films, due to the addition of C-GO nanosheets. Then, C-GO/PPy/PLLA conducting conduit with 2 mm inner diameter was prepared to bridge 10 mm sciatic nerve defect of rats, and the direction of fiber-axis in the conduit was the same as the conduit central axis. Electrical stimulation (ES) of 1 V and 20 Hz through the conducting conduit was exerted on the defect site. The results of in vivo electrophysiological and histological evaluation indicated that, the sciatic nerve defect could be repaired in C-GO/PPy/PLLA conduit, moreover the re-innervated gastrocnemius muscle and nerve conduction in C-GO/PPy/PLLA conduit & ES group were obviously better than the conduit without ES group. The results of transmission electron microscope analysis also demonstrated that the mean thickness of myelin sheath and diameter of axon in C-GO/PPy/PLLA conduit & ES group were significantly larger than those without ES, suggesting that the repair efficiency of ES & conduit group was closer to that of autograft group. These results indicated the great potential of C-GO/PPy/PLLA with the in vivo ES in the application of sciatic nerve repair.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.36781DOI Listing

Publication Analysis

Top Keywords

sciatic nerve
16
conduit group
16
c-go/ppy/plla conduit
12
conduit
9
carboxylic graphene
8
graphene oxide-composited
8
nerve repair
8
electrical stimulation
8
conducting conduit
8
nerve defect
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!