MK-7680, a cyclic nucleotide prodrug, caused significant kidney tubule injury in female rats when administered orally at 1000 mg/kg/day for 2 weeks using 10% Polysorbate 80 as vehicle. However, kidney injury was absent when MK-7680 was administered at the same dose regimen using 100% Polyethylene Glycol 200 (PEG 200) as the vehicle. Subsequent investigations revealed that MK-7680 triphosphate concentrations in kidney were much lower in rats treated with MK-7680 using PEG 200 compared with 10% Polysorbate 80 vehicle, whereas plasma exposures of MK-7680 prodrug were similar. In vitro studies demonstrated that PEG 200 is an inhibitor of human renal uptake transporter organic anion transporter 3 (OAT3), of which MK-7680 is a substrate. Furthermore, PEG 200 and PEG 400 were found to interfere in vitro with human renal transporters OAT3, organic cation transporter (OCT) 2, multidrug resistance-associated protein (MRP) 2 and 4, and multidrug and toxin extrusion protein (MATE) 1 and 2K, but not OAT1. These results support a conclusion that PEG 200 may prevent MK-7680-induced kidney injury by inhibiting its active uptake into proximal tubular cells by OAT3. Caution should be exercised therefore when using PEGs as vehicles for toxicity assessment for compounds that are substrates of renal transporters.

Download full-text PDF

Source
http://dx.doi.org/10.1093/toxsci/kfz186DOI Listing

Publication Analysis

Top Keywords

peg 200
20
glycol 200
8
organic anion
8
anion transporter
8
10% polysorbate
8
polysorbate vehicle
8
kidney injury
8
200 peg
8
human renal
8
renal transporters
8

Similar Publications

Article Synopsis
  • A study was conducted to develop and evaluate the Space Child Laparoscopic Trainer (SCLT), a low-cost, 3D-printed tool designed for pediatric laparoscopic training, to assess its effectiveness compared to a standard laparoscopic trainer (LT).
  • The SCLT was created using a 3D printer, cost five euros, and took about 10 minutes to assemble, with various aspects of performance measured through tasks completed by surgical residents and experienced surgeons.
  • Results showed that the learning speed for surgical tasks was slightly higher with the SCLT compared to the LT, indicating it may be an effective alternative for training, although further assessment on its non-inferiority suggested more research is needed.
View Article and Find Full Text PDF

Tunable Bicontinuous Macroporous Cell Culture Scaffolds via Kinetically Controlled Phase Separation.

Adv Mater

January 2025

Macromolecular Engineering Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, 8092, Switzerland.

Article Synopsis
  • 3D scaffolds provide a more natural environment for cell studies, but synthetic hydrogels often have limited pore sizes that restrict cell movement.
  • A new method using liquid-liquid phase separation creates macroporous hydrogels with adjustable pore sizes by controlling polymerization conditions like light intensity and hydrogel composition.
  • These macroporous gels, suitable for cell encapsulation, enhance cell spreading and migration, mimicking natural extracellular matrix (ECM) environments.
View Article and Find Full Text PDF

Evaluation of rheological properties of guar gum-based fracturing fluids enhanced with hydroxyl group bearing thermodynamic hydrate inhibitors.

Int J Biol Macromol

December 2024

Department of Petroleum Engineering, School of Energy Technology, Pandit Deendayal Energy University, Gandhinagar, Gujarat 382426, India. Electronic address:

Naturally occurring gas clathrates are a significant methane resource-the primary component of natural gas, regarded as the cleanest hydrocarbon and a key feedstock for producing gray and blue hydrogen. Despite the global abundance of gas hydrate reserves, extraction via depressurization has yet to achieve commercially viable production rates. The primary limitation lies in the low permeability of hydrate-bearing sediments, where solid clathrates obstruct porous pathways, hindering dissociation and slowing gas recovery.

View Article and Find Full Text PDF

In this study, polyethylene glycol (PEG) and dextran (Dex) were chemically modified to obtain amino-functionalized PEG (PEG-(NH)) and oxidized dextran (ODex). They were subsequently reacted via -NH and -CHO groups to synthesize a macromolecular Schiff base particle. The structures, morphologies, and thermal properties of the macromolecular Schiff base particle were characterized using Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and thermogravimetry analysis (TGA).

View Article and Find Full Text PDF

CY1-4, 9-nitropyridine [2',3':4,5] pyrimido [1,2-α] indole -5,11- dione, is an indoleamine 2,3-dioxygenase (IDO) inhibitor and a poorly water-soluble substance. It is very important to increase the solubility of CY1-4 to improve its bioavailability and therapeutic effect. In this study, the mesoporous silica nano-skeleton carrier material Sylysia was selected as the carrier to load CY1-4, and then the CY1-4 nano-skeleton drug delivery system (MSNM@CY1-4) was prepared by coating the hydrophilic polymer material Hydroxypropyl methylcellulose (HPMC) and the lipid material Distearoylphosphatidyl-ethanolamine-poly(ethylene glycol) (DSPE-PEG) to improve the anti-tumor effect of CY1-4.

View Article and Find Full Text PDF