Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Glutathione S-transferase (GST) is a group of multifunctional enzyme and participates in many physiological processes, such as xenobiotic biotransformation, drug metabolism, and degradation of toxic products. Herein, we demonstrate a label-free fluorescent conjugated polymer nanoparticle (FCPNPs)-based single-particle enumeration (SPE) method for the sensitive GST assay. Fluorescence resonance energy transfer (FRET) is formed between the glutathione-modified FCPNPs (FCPNPs-GSH) and polyethylenimine-capped gold nanoparticles (GNPs@PEI). Therefore, the fluorescence of FCPNPs-GSH is quenched remarkably. In the presence of GST, GNPs@PEI stay away from FCPNPs-GSH due to the specific interaction between FCPNPs-GSH and GST, leading to the inhibition of FRET. As a result, the fluorescence emission of FCPNPs-GSH is restored, which is reflected as the increase of the number of fluorescent particles in the microscopic image. By statistically counting the target concentration-dependent fluorescent particle number, accurate quantification of GST is achieved. The linear range from 0.01 to 6 μg/mL is obtained for GST assay and the limit-of-detection (LOD) is 1.03 ng/mL, which is much lower than the ensemble fluorescence spectra measurements in bulk solution. In urine sample assay, satisfactory recoveries in the range of 97.5-106.5.0% are achieved. Because of the high sensitivity and excellent specificity, this method can be extended to the detection of other disease-related biomolecules in the future.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.9b01849 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!