Purpose: To investigate the association between levels of MMP-9, a common marker of inflammation in tears, and changes to the meibomian glands accompanying soft contact lens (CL) wear.

Methods: Flush tears were collected from: (1) three groups of CL wearers who had worn CLs on a daily basis for different durations (Short: 2 ± 1 years, Moderate: 5 ± 1 years and Long experience: 10 ± 2 years); (2) a group of previous CL wearers (PWs) who had ceased wear for at least 6 months; and (3) healthy non-wearers (NW) as a control group. Total MMP-9 and its inhibitor, tissue inhibitor of MMPs-1 (TIMP-1) concentration were established using sandwich enzyme-linked immunosorbent assay. The MMP-9: TIMP-1 ratio was calculated for every individual, and then the average of all ratios for each group were compared. The non-parametric statistical Kruskal Wallis one-way analysis of variance was used for comparison, with Dunn's testing post-hoc.

Results: Tear samples from 100 participants (51 females; mean age ± SD: 25.4 ± 4.1 years) were analysed. MMP-9 concentrations and MMP-9:TIMP-1 ratio were significantly different between groups (Kruskal Wallis p = 0.001 and p < 0.001 respectively), while the concentration of TIMP-1 did not vary statistically between study groups (Kruskal Wallis, p = 0.32). Post hoc analysis indicated that only CL wearers with short experience had MMP-9 concentrations that were significantly high compared to NWs (23.1 ± 17.9 ng/mL and 4.1 ± 4.1 ng/mL, respectively, Dunn p < 0.001). Additionally, the ratio of MMP-9 to TIMP-1 concentration was only significantly greater in CL wearers with short experience (mean ratio ± SD = 1.15 ± 0.76) when compared to NWs (0.19 ± 0.29, Dunn P < 0.001), CL wearers with moderate experience (0.37 ± 0.41; P = 0.01) and PWs (0.38 ± 0.36; P = 0.02).

Conclusions: The early years of CL wear appear to be associated with increased expression of MMP-9 relative to its inhibitor TIMP-1. This may be indicative of low-level inflammation during this phase of wear. The role this plays in propagating dry eye disease and MGD in CL wear requires further exploration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2019.07.007DOI Listing

Publication Analysis

Top Keywords

soft contact
8
contact lens
8
kruskal wallis
8
mmp-9
5
relationship tear
4
tear film
4
film mmp-9
4
mmp-9 meibomian
4
meibomian gland
4
gland changes
4

Similar Publications

Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study.

Adv Sci (Weinh)

December 2024

Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.

Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.

View Article and Find Full Text PDF

In this Prentice Medal Award lecture, I shall recount my career in vision science in the context of three types of inspiration-"being inspired," "personal inspiration," and "inspiring others." My research has derived inspiration from a variety of sources, such as contemporary and historical research doyens in the ophthalmic field and beyond, artists, Greek philosophers, and abstract constructs such as principles and adages. A given moment of inspiration can range from being a profound experience to a subtle realization during a quiet moment of reflection.

View Article and Find Full Text PDF

An Octopus-Inspired Soft Pneumatic Robotic Arm.

Biomimetics (Basel)

December 2024

Department of Electrical and Computer Engineering, Hellenic Mediterranean University, GR-71410 Heraklion, Greece.

This paper addresses the design, development, control, and experimental evaluation of a soft robot arm whose actuation is inspired by the muscular structure of the octopus arm, one of the most agile biological manipulators. The robot arm is made of soft silicone and thus possesses enhanced compliance, which is beneficial in a variety of applications where the arm may come into contact with delicate features of its environment. The arm is composed of three elongated segments arranged in series, each one of which contains several pneumatically actuated chambers embedded in its silicone body, which may induce various types of deformations of the segment.

View Article and Find Full Text PDF

The inherent passive impedance characteristics of soft robotic arms provide excellent environmental adaptability. When a soft robotic arm interacts with its surroundings, its passive impedance responds swiftly, preventing rigid collisions that could damage the arm and ensuring high safety. However, during the movement of the soft robotic arm, these passive impedance properties are uncontrollable, making it impossible to achieve precise impedance control in constrained environments by relying solely on passive mechanisms.

View Article and Find Full Text PDF

A classical crystallization usually grows epitaxially from a crystal nucleus. Presented in this study is an unusual endotaxy growth manner of a crystalline homopolymer to form hexagonal nanosheets. The amphiphilic homopolymer, poly(3-(4-(phenyldiazenyl)phenoxy)propyl methacrylate) (PAzoPMA), is first annealed in isopropanol to afford a hexagonal nut-like structure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!