Purpose: Comparing radiation treatment plans by using the same safety margins and dose objectives for all techniques, to ascertain the optimal radiation technique for the stereotactic body radiotherapy (SBRT) of low-risk prostate cancer.

Material And Methods: Treatment plans for 27 randomly selected patients were compared using intensity-modulated (IMRT) techniques as Sliding Window (SW), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT), as well as Cyber Knife (CK) system. The target dose was calculated to 36.25 Gy delivered in five fractions over 1 week. Dosimetric indices for target volume and organs at risk (OAR) as well as normal tissue complication probability (NTCP) of late rectal and urinary bladder toxicities were analyzed.

Results: The CK provided lower homogeneity in the target volume, but higher values for most of the conformity indices compared to the IMRT approaches. The SW demonstrated superior rectum sparing at medium-to-high dose range (V18 Gy - V32.6 Gy) compared to other techniques (p < 0.05). The whole urinary bladder experienced the best shielding by SW and VMAT at the medium dose (V18 Gy, p < 0.05 versus CK), however we obtained no relevant differences between techniques at the high dose. Generally, the CK demonstrated significantly superior rectum and bladder exposure at V18 Gy as compared to HT, SW, and VMAT. For the rectum, mean NTCP values were significantly superior for HT (NTCP = 2.3%, p < 0.05), and for urinary bladder, the NTCP showed no significant advantages for any technique.

Conclusion: No absolute dosimetric advantage was revealed to choose between CK or IMRT techniques for the SBRT of low-grade prostate cancer. Using the same safety margins and dose objectives, IMRT techniques demonstrated superior sparing of the rectum and bladder at a medium dose compared to CK. Comparing different IMRT approaches SW displayed superior rectum sparing at a medium-to-high dose range, whereas both SW and RA revealed superior bladder sparing compared to HT. HT demonstrated a significantly lower NTCP outcome compared to CK or IMRT techniques regarding the rectum. Radiation plans can be optimized further by an individual modification of dose objectives independent of the treatment plan strategy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6689170PMC
http://dx.doi.org/10.1186/s13014-019-1353-6DOI Listing

Publication Analysis

Top Keywords

imrt techniques
8
cyber knife
8
stereotactic body
8
body radiotherapy
8
low-risk prostate
8
treatment plans
8
target volume
8
treatment planning
4
planning study
4
study comparing
4

Similar Publications

Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.

Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.

View Article and Find Full Text PDF

Purpose: To investigate the impact of Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) on hippocampal radiation dosage and psychological status in patients newly diagnosed with nasopharyngeal carcinoma (NPC).

Patients And Methods: A retrospective analysis was conducted on 269 NPC patients who received initial treatment between January 2013 and April 2022. Patients were categorized into the IMRT group and the VMAT group based on the radiotherapy technique employed.

View Article and Find Full Text PDF

Background: The purpose of this study was to compare outcomes and adverse events between three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) in patients undergoing long-course neoadjuvant radiation therapy (NA-RT) for locally advanced rectal adenocarcinoma (LARC).

Methods: We retrospectively analyzed a total of 47 consecutive patients who received NA-RT for LARC between January 2011 and September 2022. Seven and 40 patients were diagnosed with clinical stages II and III, respectively.

View Article and Find Full Text PDF

Purpose: Analyze the incidence and risk factors of thyroid dysfunction in patients with advanced nasopharyngeal carcinoma (LA-NPC) after intensity-modulated radiotherapy (IMRT) and PD⁃1 inhibitor treatment and their relationship with treatment efficacy and prognosis.

Methods: Eighty-five LA-NPC patients treated with IMRT and PD-1 inhibitors were retrospectively collected from March 1, 2019, to May 30, 2022. The incidence of thyroid dysfunction after combination therapy was analyzed.

View Article and Find Full Text PDF

Reducing radiation-induced hypothyroidism by modified delineation of cervical lymphatic drainage area for nasopharyngeal carcinoma treated by intensity-modulated radiation Therapy: 3 years' experience.

Radiother Oncol

January 2025

NHC Key Laboratory of Personalized Diagnosis and Treatment of Nasopharyngeal Carcinoma, Jiangxi Cancer Hospital, The Second Affiliated Hospital of Nanchang Medical College, Nanchang 330029, China; Department of Radiation Oncology, Jiangxi Clinical Research Center for Cancer, Jiangxi Cancer Hospital, The Second Affiliated Hospital of Nanchang Medical College, Nanchang 330029, China. Electronic address:

Background And Purpose: Radiation-induced hypothyroidism (RIHT) is a late complication of intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC). We evaluated thyroid protection in NPC patients receiving IMRT using modified delineation (MD) of cervical lymphatic drainage areas, sparing the common carotid artery within the clinical target volume (CTV), to assess its impact on thyroid function and survival outcomes.

Materials And Methods: This retrospective cohort study included patients without metastatic lymph nodes at levels III and IV who received neck irradiation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!