The present study elucidates the mechanical performance of different designs of resin-bonded fixed dental prostheses made of lithium disilicate simulating masticatory loads of anterior or canine guidance. A three-dimensional model of maxilla was constructed containing central incisor and canine teeth, with edentulous space of the lateral incisor. Three designs of prosthesis were created: retained in central incisor (1-I), retained in canine (1-C) and fixed in both teeth (2-IC). The computational analysis was performed for load in canine and central incisor separately (100N, 45°). The tensile and shear stresses were calculated for the resin-bonded fixed dental prosthesis, bonding surface of each retainer and cement layer using 3D finite element analysis. The 20 highest stress values were analyzed using two-way ANOVA and post-hoc Tukey test, all with α = 5%. The computational analysis showed that 2-retainer resin-bonded fixed dental prosthesis presented the worst prognosis regardless of the mandibular movement. ANOVA showed that Mandibular movement*Retainer interaction influenced on the tensile and shear stresses values (p < 0.01). Higher stresses were observed in the connector region for all groups (13-82.2 MPa; 11-70.2 MPa). In order to reduce the stress concentration in the resin-bonded fixed dental prosthesis and the retainer made of lithium disilicate, the occlusion may serve as the selection criteria of the unitary abutment for better sustainability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2019.103389DOI Listing

Publication Analysis

Top Keywords

resin-bonded fixed
16
fixed dental
16
central incisor
12
lithium disilicate
8
dental prostheses
8
finite element
8
element analysis
8
computational analysis
8
tensile shear
8
shear stresses
8

Similar Publications

Finite element analysis of stress distribution in cantilever resin-bonded zirconia fixed dental prosthesis and periodontal tissue with alveolar bone loss.

J Prosthodont Res

January 2025

Department of Masticatory Function and Health Science, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.

Purpose: To compare the stress distribution in loaded zirconia resin-bonded fixed dental prostheses (RBFDPs) and periodontal tissue using finite element analysis, considering reduced alveolar bone levels and the number of retainers.

Methods: A human skull was micro-CT scanned. Three framework designs were tested: a 2-unit RBFDP using the maxillary left central incisor (#21) as an abutment, another using a canine (#23), and a 3-unit RBFDP using both #21 and #23.

View Article and Find Full Text PDF

Objectives: To prospectively evaluate the wear of posterior zirconia resin-bonded fixed partial dentures (RBFPDs) with polished occlusal surfaces and their natural enamel antagonists compared to contralateral controls in an enamel-enamel contact over 5 years.

Materials And Methods: In six patients with either an inlay- or wing-retained RBFPD made of monolithic 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), wear was evaluated indirectly using baseline and annual polyvinyl siloxane impressions. Resulting gypsum models were digitized and aligned by unchanged surface areas.

View Article and Find Full Text PDF

Introduction: The aim of this systematic review was to determine the best treatment alternatives for patients with maxillary lateral incisor agenesis (MLIA) by comparing orthodontic space closure, implant and tooth supported dental prostheses by assessing studies that evaluated their periodontal, occlusal (function) and aesthetic results.

Methods: The present systematic review was reported according to the indications of the preferred reporting items for systematic reviews and meta-analysis (PRISMA) incorporating network meta-analysis, and the protocol was registered with PROSPERO (CRD42023487245). The PRISMA systematic search, without restriction on language or initial date, was carried out using electronic databases: MEDLINE (PubMed), Scopus and central register of controlled trials.

View Article and Find Full Text PDF

In essence the resin-bonded fixed partial denture, or resin-bonded bridge, is an artificial tooth that is bonded to 1 or 2 abutment teeth. If the resin-bonded bridge is directly made with resin composite intra-orally, then the connector area is the weakest link. The alternative is to produce an indirect resin-bonded bridge in which a metal or ceramic frame spans the space between the abutments.

View Article and Find Full Text PDF

Bridges are commonly used to replace missing teeth. This article provides a comprehensive overview of the key factors influencing the performance and lifespan of various types of resin-bonded fixed prostheses. Studies comparing different types underscore the importance of achieving a balance between structural integrity and stress distribution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!