A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of physiotherapy ultrasound beam quality parameters from images derived using thermochromic material. | LitMetric

Determination of physiotherapy ultrasound beam quality parameters from images derived using thermochromic material.

Ultrasonics

Clinical Hospital Center Rijeka, Krešimirova 42, 51 000 Rijeka, Croatia; University of Rijeka, Faculty of Medicine, Department of Medical Physics and Biophysics, Braće Branchetta 20, 51 000 Rijeka, Croatia. Electronic address:

Published: November 2019

The evaluation of the performance of nine physiotherapy ultrasound transducers used clinically was performed in the hospital environment using an acoustically absorbing thermocromic tile developed at the National Physical Laboratory (UK). The method consists of exposing an acoustic absorber tile, part of which contains a thermochromic pigment, to the ultrasonic beam, thereby forming an image of the intensity profile of the transducer. Images acquired using thermochromic materials were postprocessed in order to estimate effective radiating area (ERA) and beam nonuniformity ratio (BNR) for ultrasound transducers operating within the frequency range from 1.0 to 3.3 MHz, and nominal applied intensities in the range of 1-2W/cm. Results of our measurements have shown that thermocromic tile can be used for quality control of ultrasound transducers in the hospital environment. Experimental results show that proposed method can be used to distinguish highly non - uniform ultrasound beams with high value of BNR. Influence of exposure duration on obtained ERA and BNR values was also analysed. Our results show that values for ERA increase with insonation time, while BNR values decrease. In order to compare our results with theory we have estimated temperature rise in thermochromic material experimentally and compare it with theoretical prediction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2019.06.005DOI Listing

Publication Analysis

Top Keywords

ultrasound transducers
12
physiotherapy ultrasound
8
thermochromic material
8
hospital environment
8
thermocromic tile
8
bnr values
8
ultrasound
5
determination physiotherapy
4
ultrasound beam
4
beam quality
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!