A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Systems-Based Analysis of the CardioMEMS HF Sensor for Chronic Heart Failure Management. | LitMetric

Background: Hemodynamic-guided therapy using the CardioMEMS™ system has been shown to reduce heart failure hospitalization (HFH) in both clinical trials and real-world settings. However, the CardioMEMS system requires input from multiple independent elements to achieve its effect, and no studies have been done to investigate those elements. Consistent patient participation and health care provider participation are two of those key elements, and this study sought to assess how they affect HFHs.

Methods: This was a single-center, retrospective cohort study of patients with the CardioMEMS sensor. The primary outcome was the number of HFH days patients experienced in the 1 year following CardioMEMS sensor implant. The primary independent variables were the average number of days between patient transmissions of data and the average number of days between health care provider reviews of those data. Covariates included patient demographics, medical comorbidities, history of HFHs, and initial pressure response to hemodynamic-guided therapy at 28 days after implant. Data were fit to a zero-inflated negative binomial regression.

Results: Seventy-eight patients were included in the study. The mean age was 64 ± 15 years, 52 (67%) were male, and 58 (76%) had heart failure with reduced ejection fraction. During the study period, there were 538 cumulative HFH patient-days. Based on the regression model, there was an exponential relationship between HFH days and the mean number of days between patient transmissions (IRR = 1.74, 95% CI: 1.09-2.75, =0.019). There was also an exponential relationship between HFH days and the mean number of days between health care provider reviews (IRR = 1.03, 95% CI: 1.01-1.05, =0.013).

Conclusions: This single-center study suggests that more frequent patient transmissions and health care provider reviews of the CardioMEMS system are associated with a decreased number of HFH days, but larger multicentered studies are required. Further systems-based analyses of the CardioMEMS system may be a useful approach to guiding effective use of the CardioMEMS device.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664522PMC
http://dx.doi.org/10.1155/2019/7979830DOI Listing

Publication Analysis

Top Keywords

health care
16
care provider
16
hfh days
16
number days
16
cardiomems sensor
12
heart failure
12
cardiomems system
12
patient transmissions
12
provider reviews
12
days
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!