AI Article Synopsis

  • A novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous measurement of Olmesartan and hydrochlorothiazide in human plasma, utilizing simple liquid-liquid extraction for sample pretreatment.
  • The method demonstrated excellent linearity, precision, and accuracy across a wide range of concentrations for both drugs, outperforming previous solid-phase extraction techniques in efficiency and cost-effectiveness.
  • Successful application of this method was shown in a bioequivalence study involving healthy subjects who received a combined formulation of the two medications.

Article Abstract

A new, simple, sensitive, selective, rapid, and high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for simultaneous quantification of Olmesartan and hydrochlorothiazide in human plasma. Simple liquid-liquid extraction procedure was applied for plasma sample pretreatment using a mixture of diethyl ether and dichloromethane, as an extraction solution. Analytes were separated on UNISOL C18 150*4.6 mm, 5 µm column using methanol, and 2 mM ammonium acetate pH 5.5 (80:20, v/v) as a mobile phase and detected by electrospray ionization in the multiple reaction monitoring (MRM) mode. The mass transition ion pairs were followed in negative ion mode as m/z 445.20 → 148.90 for Olmesartan; m/z 451.40 → 154.30 for Olmesartan D and m/z 295.80 → 205.10 for hydrochlorothiazide; m/z 298.90 → 206.30 for hydrochlorothiazide C D. The method showed excellent linearity ( > 0.99) over the concentration range of 5.002-2,599.934 ng/ml for Olmesartan and from 3.005 to 499.994 ng/ml for hydrochlorothiazide. Precision (% CV) and accuracy (% bias) for Olmesartan were found in the range of 3.07-9.02% and -5.00-0.00%, respectively. Precision (% CV) and accuracy (% bias) for hydrochlorothiazide were found in the range of 3.32-8.21% and 1.99-3.80%, respectively. This as developed novel and high-throughput liquid-liquid extraction bioanalytical method has substantial innovative value with the benefits of cost effectiveness, good extraction efficiency, shorter analysis run time, low organic solvent consumption, and simpler procedure over the previously reported solid-phase extraction method. The application of this method in pharmacokinetic studies was further demonstrated successfully through a bioequivalence study conducted on healthy human subjects, following oral administration of combined formulation of Olmesartan medoxomil and hydrochlorothiazide in fixed-dose tablet.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664239PMC
http://dx.doi.org/10.3389/fphar.2019.00810DOI Listing

Publication Analysis

Top Keywords

simultaneous quantification
8
quantification olmesartan
8
olmesartan hydrochlorothiazide
8
hydrochlorothiazide human
8
human plasma
8
bioequivalence study
8
liquid-liquid extraction
8
olmesartan m/z
8
precision accuracy
8
accuracy bias
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!