Objectives: Enamel thickness determination by Cross-Polarization Optical Coherence Tomography (CP-OCT) is a promising approach for quantitative monitoring of tooth wear progression. This study evaluated the ability of CP-OCT to quantify the thickness of natural enamel before, during and after tooth wear simulation.
Materials And Methods: Natural, unpolished human dental enamel slabs were submitted to five wear stages (Wear 1: to level the surfaces; Wear 2 to Wear 5: 0.05±0.02mm reduction each) simulated by an automatic grinding/polishing machine. Enamel thickness was evaluated with CP-OCT and a gold-standard method (micro-CT) at baseline and after every wear stage. Data were analyzed using ANOVA with pairwise comparisons for wear stages' impact on the thickness and wear depth measurements. The inter-method agreement was analyzed using intra-class correlation coefficients, the difference between means, and Bland-Altman plots.
Results: Enamel thickness measurements (mean±standard error, in mm) with natural (1.40±0.05) and worn surfaces (1.08±0.02) by CP-OCT did not differ significantly from those measured by micro-CT (natural=1.39±0.05; worn=1.09±0.02; p-values=0.30 and 0.39, respectively). CP-OCT and micro-CT showed excellent agreement on natural (ICC=0.98) and worn surfaces (ICC=0.98) enamel thickness measurements. Among and between wear stages, there were significant differences in enamel thickness and wear depth measurements for both methods (p-value <0.0001 for all). Both methods yielded similar measurements' mean (0.14±0.01; p-value=0.87) and were in good agreement (ICC=0.77) for wear depth estimation.
Significance: CP-OCT allows accurate measurement of enamel thickness on natural tooth surfaces. Enamel thickness measurement by CP-OCT allows quantitative monitoring of enamel thickness changes and wear depth following progressive wear.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.dental.2019.07.018 | DOI Listing |
BMC Oral Health
January 2025
Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, No.22, Zhongguancun South Avenue, Haidian District, Beijing, 100081, PR China.
Background: Establishing accurate, reliable, and convenient methods for enamel segmentation and analysis is crucial for effectively planning endodontic, orthodontic, and restorative treatments, as well as exploring the evolutionary patterns of mammals. However, no mature, non-destructive method currently exists in clinical dentistry to quickly, accurately, and comprehensively assess the integrity and thickness of enamel chair-side. This study aims to develop a deep learning work, 2.
View Article and Find Full Text PDFJ Oral Biol Craniofac Res
December 2024
Department of Oral Biology and Oral Pathology, Saveetha Dental College and Hopsitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 600077, India.
Introduction: Enamel translucency, essential for the aesthetic appeal of teeth, is primarily determined by its thickness, quality, and refractive index. Several factors, including age, genetics, diet, oral hygiene practices, fluoride exposure, and acidic challenges, can influence enamel translucency. Tobacco use, in particular, leads to significant alterations in enamel appearance by penetrating its micropores, causing yellowing and browning.
View Article and Find Full Text PDFJ Periodontal Res
January 2025
Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria.
Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks.
Clin Adv Periodontics
January 2025
Department of Orthodontics and Dentofacial Orthopedics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.
Background: Gingival recession defects (GRDs) pose functional and esthetic concerns and may be associated with unfavorable tooth positions. Surgically facilitated orthodontic treatment (SFOT) with clear aligners can be a valuable option for adults with severe malocclusion and GRDs.
Methods: A 28-year-old male presented with severe dental crowding, Class III dental malocclusion, localized tooth crossbites, and tapered maxillary arch.
Dent Mater
January 2025
Department of Biomaterials, School of Dentistry, University of São Paulo, Sao Paulo, Brazil.
Objective: To analyze the impact of the translucency/opacity of two commercial brands of resin cements and different translucency of lithium disilicate on the masking ability of saturated substrates.
Methods: 120 samples (n = 5) were prepared using 0.5 mm lithium disilicate (IPS e.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!