Knee arthroscopy may be called the most commonly and increasingly performed orthopaedic procedure. Posterior medial compartment visualization may be quite challenging. The aim of the present study is to detect objective measurement of medial joint space widening with percutaneous "pie crust" release of medial collateral ligament (MCL) during knee arthroscopy. We used this technique for all knees that require any intervention in the posteromedial compartment and for tight knees in which adequate visualization of the posteromedial compartment cannot be obtained. Eighteen patients (18 knees) were included in this study. Patients were evaluated clinically with the Lysholm and Tegner scores at the final office visit. Joint balance, valgus instability, pain or tenderness on MCL region, and numbness over the medial side of the joint were also noted. Measurements of medial joint space (mm) were obtained at three different times with perioperative C-arm images: normal, controlled valgus force, and after pie crusting. The median follow-up time was 9 (6-12) months. Final follow-up Lysholm ( < 0.05) and Tegner scores ( < 0.05) increased significantly compared with preoperative scores. At the final follow-up, there was no pain or tenderness over MCL and there were no signs of saphenous nerve or vein injury. Medial joint space values in after pie crusting increased significantly ( < 0.05) compared with neutral position measurements and controlled valgus force application ( < 0.05). Controlled release of the MCL in knees provided ∼2.45 times wider visualization place. Furthermore, pie crusting of MCL is a safe and effective technique that provides enough space for visualization and instrumentation in knees. This is a Level IV study.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0039-1694711DOI Listing

Publication Analysis

Top Keywords

medial joint
16
joint space
16
knee arthroscopy
12
objective measurement
8
medial
8
measurement medial
8
space widening
8
widening percutaneous
8
percutaneous "pie
8
"pie crust"
8

Similar Publications

Introduction: The medial patellofemoral ligament (MPFL) is the main patellar stabilizer in low knee flexion degrees (0-30°). Isolated MPFL reconstruction (MPFLr) is therefore considered the gold standard of surgical procedures for low flexion patellofemoral instabilities (PFIs). Despite excellent clinical results, little is known about the effect of MPFLr on kinematic parameters (KPs) of the patellofemoral joint in vivo.

View Article and Find Full Text PDF

Introduction: During tasks like minimally invasive surgery (MIS), various factors can make working environment not be ergonomic, and those situations will accumulate fatigue in the surgeon's muscles which will inevitably lead to poor surgical performance. Therefore, there has been a need for technical solutions to solve this problem and one of the methods is exoskeleton robots.

Methods: We designed a passive shoulder exoskeleton whose workspace could be used for MIS to assist the surgeon's movements and performed computational and clinical validation.

View Article and Find Full Text PDF

Background: Traditional examinations of anterior cruciate ligament (ACL) injuries focus primarily on static assessments and lack the ability to evaluate dynamic knee stability. Hence, a dynamic scoring system for knee function is needed in clinical settings. This study aimed to propose a dynamic scoring system based on a large sample of normative six-degree-of-freedom (6-DOF) knee kinematics during gait, and validate its correlation with conventional outcome measurements in assessing ACL-injured knees.

View Article and Find Full Text PDF

Lumbar facet joints are the source of pain in 15%-41% of individuals experiencing low back pain (LBP). Conventional lumbar facet radiofrequency ablation (RFA) has Level II evidence for improving pain and function. The best proven technique, the parallel technique, is technically challenging, time-consuming, and often uncomfortable for the patient.

View Article and Find Full Text PDF

Arthroscopic evaluation of anatomical variations of the oblique popliteal ligament and their association with popliteal cyst formation.

Orthop Traumatol Surg Res

December 2024

Pôle Aixois de Chirurgie Articulaire et Sportive, La Bastide d'Axium, 21, Avenue Alfred Capus, 13090 Aix-en-Provence, France.

Introduction: The posteromedial compartment of the knee houses several important anatomical structures, including the oblique popliteal ligament (OPL), an accessory insertion tendon of the semimembranosus muscle. Popliteal cysts develop from the synovial bursa located between the medial gastrocnemius and the semimembranosus, typically secondary to intra-articular pathologies causing effusion. This study aimed to describe the normal anatomy of the postero-medial capsule of the knee and its anatomical variations, particularly in the presence of popliteal cysts.