Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The multidrug-resistant yeast pathogen continues to cause outbreaks and clusters of clinical cases worldwide. Previously, we developed a real-time PCR assay for the detection of from surveillance samples (L. Leach, Y. Zhu, and S. Chaturvedi, J Clin Microbiol 56:e01223-17, 2018, https://doi.org/10.1128/JCM.01223-17). The assay played a crucial role in the ongoing investigations of the outbreak in New York City. To ease the implementation of the assay in other laboratories, we developed an automated sample-to-result real-time PCR assay using the BD Max open system. We optimized sample extraction at three different temperatures and four incubation periods. Sensitivity was determined using eight pools of patient samples, and specificity was calculated using four clades of and closely and distantly related yeasts. Three independent extractions and testing of two patient sample pools in quadruplicate yielded assay precision. BD Max optimum assay conditions were as follows: DNA extraction at 75°C for 20 min and the use of PerfeCTa multiplex quantitative PCR (qPCR) ToughMix. The limit of detection (LOD) of the assay was one CFU/PCR. We detected all four clades of without cross-reactivity to other yeasts. Of the 110 patient surveillance samples tested, 50 were positive for using the BD Max system with 96% clinical sensitivity and 94% accuracy compared to the results of the manual assay. The BD Max assay allows high-throughput screening of 180 surveillance samples in a 12-h workday.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6760950 | PMC |
http://dx.doi.org/10.1128/JCM.00630-19 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!