This clinical study aimed to clinically and radiographically compare the implant survival rate and peri-implant tissue response between immediate and delayed loading protocols for unsplinted implant retained mandibular overdentures. Twenty patients were enrolled to participate in this study. Each subject was randomly assigned to 1 of 2 treatment groups: test group patients' implants (n = 10), which were immediately loaded, and control group patients' implants (n = 10), which were conventionally loaded. Locator abutments were torqued to 15 Ncm at delivery. Attachments were picked up intraorally immediately after implant placement for the test group and at 3 months for the control group, and 3-lb retention inserts were placed. Marginal bone levels based on cone beam computed tomography fixed reference points were recorded at baseline and 12 months. Modified plaque index, gingival index, and implant stability quotients were recorded at baseline, 3 months, and 12 months. After 12 months, implant survival rate was 100% in both groups. Marginal bone levels, keratinized mucosa, modified plaque index, and gingival index were significantly different among the groups at 3- and 12-month intervals, whereas no significant differences were found in implant stability quotients between the groups. The fact that implant survival rate was 100% in both treatment groups suggests that, within the limitations of this study, immediate loading protocol for unsplinted implant retained mandibular complete overdenture is as predictable, safe, and successful as the delayed loading protocol. Implementing the immediate loading protocol for mandibular implant retained overdentures could shorten treatment time, which could lead to better patient's satisfaction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1563/aaid-joi-D-18-00202 | DOI Listing |
J Am Acad Orthop Surg
November 2024
From the Medical University of South Carolina, Charleston, SC (Gross and Scott), the University of California Irvine, Orange, CA (Hsu), and the Palomar Health Medical Group, San Diego, CA (Palanca).
The design of total ankle arthroplasty (TAA) systems is rapidly evolving as device companies try to keep pace with the expansion of surgical indications and a refinement of techniques for TAA. Even since the publication of the latest "update," published in 2018, three new designs and three updates on preexisting third-generation implants came onto the market. Improvements in third-generation TAA systems include minimal bone resection, retaining ligamentous support, and anatomic balancing.
View Article and Find Full Text PDFJ Periodontol
January 2025
Department of Biomedical and Neuromotor Sciences, School of Dentistry - Division of Periodontology and Implantology, Alma Mater Studiorum - University of Bologna, Bologna, Italy.
Background: Crown cementation is a common technique for implant-supported prosthodontics. However, for possible slipping of the cement below the mucosal margin, its thorough removal poses some issues. The objective of this study was to evaluate the presence of submucosal cement residues in patients with peri-implant disease by endoscopic visualization and to investigate the potential correlation between the pathological scenario and the spatial position of cement residues.
View Article and Find Full Text PDFBiomaterials
January 2025
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA. Electronic address:
Direct pacing of the mid myocardium where re-entry originates can be used to prevent ventricular arrhythmias and circumvent the need for painful defibrillation or cardiac ablation. However, there are no pacing electrodes small enough to navigate the coronary veins that cross these culprit scar regions. To address this need, we have developed an injectable ionically conductive hydrogel electrode that can fill the epicardial coronary veins and transform them into flexible electrodes.
View Article and Find Full Text PDFTissue Eng Part A
January 2025
C. Wayne McIlwraith Translational Medicine Institute, Colorado State University, Fort Collins, Colorado, USA.
Scaffolds made from cartilage extracellular matrix are promising materials for articular cartilage repair, attributed to their intrinsic bioactivity that may promote chondrogenesis. While several cartilage matrix-based scaffolds have supported chondrogenesis and/or , it remains a challenge to balance the biological response (e.g.
View Article and Find Full Text PDFSICOT J
January 2025
Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia.
Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!