Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: A drain exchange with the use of a guidewire may be accompanied by serious complications.
Case Presentation: This case involved an 86-year-old man with overlapping cancers of intrahepatic cholangiocarcinoma and perihilar cholangiocarcinoma. A left hepatectomy, a left caudal lobectomy (with a medial hepatic vein preservation), an extrahepatic bile duct resection, and a right hepatojejunostomy were performed. The abdominal drain was placed into the hepatectomy side. Bile leakage occurred on the seventh day after the surgery, and the drain was exchanged. Since the bile leakage was still detectable via a computed tomography (CT) scan on the 15th postoperative day, the drain was exchanged again. On the next day, blood had discharged from the drain. A CT scan revealed that the tip of the drain was straying into the right atrium (RA) and the drain was removed from the inferior vena cava (IVC) under general anesthesia. One week later, a fiburin thrombus was observed from the IVC to the RA via the use of transthoracic echocardiography. A right atrial incision, a thrombus removal, and a middle hepatic vein merging section closure surgery were performed. Afterward, the patient's general condition gradually improved, and he was transferred to the hospital for rehabilitation.
Conclusion: More careful guidewire operations are necessary at the time of the exchange of the drain to prevent the drain from being placed too close to blood vessels.